Service Manual for the Thermador Pro Grand Next Generation 48-Inch Natural Gas and LP Gas Ranges, Models:
PRG486JDG/01, PRL486JDG/01
58300000159722_ARA_EN_D
Page 64 of 92
6.8.5
Electrical Wiring Connections at the Terminal Block
For electrical wiring requirements and safety precautions, refer to the
Installation Manual for this appliance.
NOTE:
The electrical wiring diagram is located on the back side of the
kick panel (see
page 6
6.8.6
Cooling Fan Removal and Replacement
Be sure to check QuickFinder for relevant information,
documentation, and the correct part number when replacing this
component.
Sharp Component – Use Gloves
Use gloves when handling the cooling fan, as it has sharp edges
Figure 94: Typical Cooling Fan (View from Under the Mounting Bracket)
1
Screw locations (2) securing bracket onto the range.
Figure 95: Another Typical Cooling Fan (View from Under the
Mounting Bracket)
1
Screw locations (4) securing bracket onto the range
1. Follow all safety precautions and steps in
procedure, page
3. At the back of the range, detach the cooling fan wire connectors,
and make a note of which wires are connected to each of the two
different terminals.
NOTE:
It is always recommended to label and tag all wires, wire
connectors and harnesses prior to disconnecting them, so as to
correctly identify their connections/locations when reassembling.
Alternatively, you can photograph the wire connections prior to
disconnecting (for example, with your mobile phone).
4. Remove and retain the screws that secure the cooling fan
mounting bracket onto the range chassis (see Figure 94
and Figure 95).
NOTE:
For some cooling fans, to remove the screws from the
bracket, from under the maintop, insert the screwdriver through
the access holes on the chassis (see Figure 96, page 65).