Teledyne API Model T360/T360M Operation Manual
Operating Instructions
121
5. In the instrument’s SETUP>MORE>COMM>COM2 menu, make the following
settings:
B
aud Rate: 115200
COM2 Mode Settings:
Quiet Mode
ON
Computer Mode
ON
MODBUS RTU
OFF
MODBUS ASCII
OFF
E,8,1 MODE
OFF
E,7,1 MODE
OFF
RS-485 MODE
OFF
SECURITY MODE
OFF
MULTIDROP MODE
OFF
ENABLE MODEM
OFF
ERROR CHECKING
ON
XON/XOFF HANDSHAKE
OFF
HARDWARE HANDSHAKE OFF
HARDWARE FIFO
ON
COMMAND PROMPT
OFF
6. Next, configure your communications software, such as APIcom. Use the
COM port determined in Step 4 and the baud rate set in Step 5. The figures
below show how these parameters would be configured in the Instrument
Properties window in APIcom when configuring a new instrument. See the
APIcom manual (PN 07463) for more details.
Note that USB configuration requires that baud rate (Section 4.11.10) of
instrument and PC match. Also, using the USB port disallows use of the rear
panel COM2 port except for multidrop communications (Section 4.11.8).
07272B DCN6552
Summary of Contents for T360
Page 2: ......
Page 188: ...This page intentionally left blank 07272B DCN6552 ...
Page 264: ...07272B DCN6552 ...
Page 320: ...This page intentionally left blank B 2 07272B DCN6552 ...
Page 324: ...This page intentionally left blank B 6 07272B DCN6552 ...
Page 327: ...APPENDIX D Wire List and Electronic Schematics D 1 07272B DCN6552 ...
Page 328: ...This page intentionally left blank D 2 07272B DCN6552 ...
Page 332: ...This page intentionally left blank 07272B DCN6552 D 6 ...
Page 333: ...07272B DCN6552 D 7 ...
Page 338: ...07272B DCN6552 D 12 ...