Teledyne LeCroy
Projects
72
Sierra M6
‐
2 SAS/SATA Protocol Analyzer User Manual
Protocol Error Descriptions
SMP
Response
Time
Limit
: is outside the specification requirements.
Code
Violation
: Wrong 10b symbol detected.
Disparity
Error
: Wrong disparity detected.
ALIGN
Error
: ALIGN primitive frequency is outside the specification requirements.
STP
Signaling
Latency
Error
[SAS
only]
or
FIS
Signaling
Latency
Error
[SATA
only]
:
DWORD difference between HOLD and HOLDA is greater than entered value in the HOLD/
HOLDA Response Timeout field.
STP
Invalid
State
Transition
(Unexpected
Primitive)
[SAS
only]
or
FIS
Invalid
State
Transition
(Unexpected
Primitive)
[SATA
only]
: Second SATA_SOF is encountered before
SATA_EOF, and other unexpected primitives.
STP
Invalid
State
Transition
(Primitive
Timeout)
[SAS
only]
or
FIS
Invalid
State
Transition
(Primitive
Timeout)
[SATA
only]
: Timeout between two paired primitives is above
entered value. 65000 DWORDs is default. For example, it can occur between WTRM and
R_OK, or X_RDY and R_RDY. It expects device (or host) to send a response, but response is
not received after 65000 DWORDs. You can configure Primitive Response Timeout and
HOLD/HOLDA Response Timeout in the Settings tab Analyzer Settings section.
Frame
Type
Error
: Wrong frame type.
Frame
Length
Error
: Reported frame length is different than actual frame length:
Frame
Direction
Error
: Wrong frame direction. For example, Register Device to Host
coming from the Host.
CRC
Error
: CRC error detected.
ACK/NAK
Timeout
[SAS
only]
: ACK or NAK primitive missing or encountered
unexpectedly.
Delimiter
Error
: Detects two SOF primitives without an EOF between them. Also detects
two EOF primitives without an SOF between them.
Radio
Buttons
: All, SSP, SMP and STP
‐
By selecting one of these radio boxes you can
specify that you want to trigger(or filter) on a specific protocol error on a specified frame
type. If you check CRC error and select the SSP radio button, if a CRC error occurs on a
SMP frame, the analyzer does not trigger on it.
Hashed
Destination
SAS
Address
(SSP
trigger
only)
: Specify the destination address for
the analyzer to locate specific protocol errors.
Hashed
Source
SAS
Address
(SSP
trigger
only):
Specify the source address for the
analyzer to locate specific protocol errors.
Summary of Contents for Sierra M6-2
Page 37: ...Sierra M6 2 SAS SATA Protocol Analyzer User Manual 35 Expandability Teledyne LeCroy ...
Page 375: ...Sierra M6 2 SAS SATA Protocol Analyzer User Manual 373 Interface Teledyne LeCroy ...
Page 436: ...Teledyne LeCroy Scenario Batch Files 434 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Page 526: ...Teledyne LeCroy 524 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...