Teledyne LeCroy
Performance Analysis
180
Sierra M6
‐
2 SAS/SATA Protocol Analyzer User Manual
Enter a SAS Source Address to include in the performance calculation.
SAS
Destination
Address
(SAS
only)
Enter a SAS Destination Address to include in the performance calculation.
Define Performance
Click the
Performance
Item
check box in the Performance Items tab. Performance
measurement has the following categories:
Link Usage:
Bus Utilization (Ratio of frame time to update interval)
Transmission Efficiency (Ratio of payload time to frame time)
Throughput (Quantity of payload or useful data transferred during update
interval)
Average Payload Size (Ratio of overall payload size to number of data frame)
Completed Command Rate (Ratio of completed commands to total com
‐
mands)
Data Efficiency (Ratio of data payload time to data frame time)
Event Counts:
Number of Frame Events
SCSI Command Number
Number of Data Frame Events
Number of Protocol Errors
Number of Frame Errors
Event Times:
Total Frame Event Time
Total Data Frame Time
Total Data Payload Time
Total Idle Time
Settings
Click the
Setting
tab to display the settings dialog.
Summary of Contents for Sierra M6-2
Page 37: ...Sierra M6 2 SAS SATA Protocol Analyzer User Manual 35 Expandability Teledyne LeCroy ...
Page 375: ...Sierra M6 2 SAS SATA Protocol Analyzer User Manual 373 Interface Teledyne LeCroy ...
Page 436: ...Teledyne LeCroy Scenario Batch Files 434 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Page 526: ...Teledyne LeCroy 524 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...