Teledyne LeCroy
Emulation
150
Sierra M6
‐
2 SAS/SATA Protocol Analyzer User Manual
Select the
Close
Sequence
Type
from the drop
‐
down list. Selecting
Delay in sending
allows you to specify the delay in sending Done, Close, or Break.
Select the
Close
Connection
Settings
from the drop
‐
down lists.
Outgoing
Open
Error
Check Outgoing Open Error and then the enabled Error Settings button to display the
Open Frame Setting dialog.
Figure 2.158: Open Frame Setting Dialog
Check errors to introduce.
Scroll through the available choices in the Destroy Field of Frame list box and check the
field to destroy.
Incoming
Open
Primitive
Response
Check this box, then click the down arrow next to the Primitive list box and choose a
response type. Enter a Delay value.
Figure 2.159: Incoming Open Primitive Response Dialog
Affiliation
Setting
Check Clear Affiliation After Command Complete to release device to commands from
other sources, or check Leave Affiliation State Unchanged to retain control of device.
Enable
First
Burst
Check Enable First Burst to allow first burst.
Task
Attribute
Choose Simple, Head of Queue, Ordered, or ACA.
Outgoing ATA Frame Settings
Before selecting Outgoing Frame Settings, select the Types Of Frames and the Frame
Number on which to inject an error. Then check Outgoing Frame in the Generate Error On
Summary of Contents for Sierra M6-2
Page 37: ...Sierra M6 2 SAS SATA Protocol Analyzer User Manual 35 Expandability Teledyne LeCroy ...
Page 375: ...Sierra M6 2 SAS SATA Protocol Analyzer User Manual 373 Interface Teledyne LeCroy ...
Page 436: ...Teledyne LeCroy Scenario Batch Files 434 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Page 526: ...Teledyne LeCroy 524 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...