Model 2281S-20-6 DC Power Supply and Battery Simulator Reference Manual
Section 7: SCPI command reference
077114601 / March 2019
7-149
Example
:STAT:MEAS:ENAB #b0010000000000000
Sets the ISUM bit of the measurement
status enable register using a binary
value.
You could also send the decimal value
8192
or the hexadecimal value:
#h2000
.
Also see
(on page D-17)
:STATus:MEASurement:INSTrument[:EVENt]?
This command reads and clears the Measurement Instrument Event Register of the status model.
Type
Affected by
Where saved
Default value
Query only
Not applicable
Not applicable
Not applicable
Usage
:STATus:MEASurement:INSTrument[:EVENt]?
Details
This attribute reads the Measurement Instrument Event Register of the status model and then clears
the register.
The instrument returns a decimal value that corresponds to the binary-weighted sum of all bits set in
the register. For details, see
Measurement Instrument Event Register
(on page D-18).
Also see
None
:STATus:MEASurement:INSTrument:ENABle
This command sets or reads the contents of the Measurement Instrument Event Enable Register of the status
model.
Type
Affected by
Where saved
Default value
Command and query
Power cycle
Not applicable
0
Usage
:STATus:MEASurement:INSTrument:ENABle <n>
:STATus:MEASurement:INSTrument:ENABle?
[n]
The status of the Measurement Instrument Enable Register.
Details
This command sets or reads the contents of the enable register of the Measurement Instrument
Event Register.
When one of these bits is set and the corresponding bit in the Measurement Instrument Event
Register is set, the ISUM bit in the Measurement Event Register is set.