Appendix A: Performance Characteristics
AĆ14
DG2020A, P3410, & P3420 User Manual
Certification and Compliances
The certification and compliances for the DG2020A are listed in Table A-8.
Table AĆ8: Certifications and compliances
Category
Standards or description
EC Declaration of Conformity -
EMC
Meets intent of Directive 89/336/EEC for Electromagnetic Compatibility. Compliance was
demonstrated to the following specifications as listed in the Official Journal of the European
Communities:
EMC Directive 89/336/EEC:
EN 55011
Class A Radiated and Conducted Emissions
EN 50081Ć1
Emissions:
EN61000Ć3Ć2
AC Power Line Harmonic Emissions
EN 50082Ć1
Immunity:
EN61000Ć4Ć2
Electrostatic Discharge Immunity
EN61000Ć4Ć3
RF Electromagnetic Field Immunity
EN61000Ć4Ć4
Electrical Fast Transient/Burst Immunity
EN61000Ć4Ć6
Conducted Disturbance Induced by Radio-frequency Field
EN61000Ć4Ć8
Power Frequency Electromagnetic Field Immunity
EN61000Ć4Ć11
Voltage Dips and Interruptions Immunity
Australian/New Zealand
declaration of Conformity Ć EMC
Complies with EMC provision of Radio-communications Act per the following standard:
AS/NZS 2064.1/2
Industrial, Scientific, and Medical Equipment: 1992
EC Declaration of Conformity -
Low Voltage
Compliance was demonstrated to the following specification as listed in the Official Journal of the
European Communities:
Low Voltage Directive 73/23/EEC, amended by 93/68/EEC
EN 61010Ć1/A1:1992
Safety requirements for electrical equipment for
measurement, control and laboratory use.
Approvals
Complies with the following safety standards:
UL3111-1
1
, First Edition
Standard for electrical measuring and test equipment.
CAN/CSA C22.2 No.1010.1Ć92
1
Safety requirements for electrical equipment for
measurement, control and laboratory use.
Installation Category Description
Terminals on this product may have different installation (over-voltage) category designations. The
installation categories are:
Category
Examples of products in this category
CAT III
DistributionĆlevel mains (usually permanently connected). Equipment at this
level is typically in a fixed industrial location.
CAT II
LocalĆlevel mains (wall sockets). Equipment at this level includes appliances,
portable tools, and similar products. Equipment is usually cordĆconnected.
CAT I
Secondary (signal level) or battery operated circuits of electronic equipment.
Summary of Contents for DG2020A
Page 2: ...User Manual DG2020A Data Generator With P3410 P3420 Pods 071 0053 50 www tektronix com...
Page 5: ......
Page 15: ...Table of Contents DG2020A P3410 P3420 User Manual...
Page 19: ...Service Safety Summary DG2020A P3410 P3420 User Manual...
Page 50: ...Operating Basics DG2020A P3410 P3420 User Manual 2 15 Figure 2 10 Data structure image...
Page 69: ...Basic Menu Operation DG2020A P3410 P3420 User Manual...
Page 181: ...APPLICATION Menu DG2020A P3410 P3420 User Manual...