This test confirms the frequency precision of the DG2020A internal clock.
With the PLL circuit on: Clock frequency
50 ppm
With the PLL circuit off: Clock frequency
3%
Required Equipment
Frequency counter
SMB-to-BNC cable
50
W
termination
N-to-BNC adapter
Performance check disk
Connections.
Connect the clock output from the DG2020A rear panel to the
frequency counter input (INPUT B) through the N-to-BNC adapter with the
SMB-to-BNC cable.
Figure BĆ3: Frequency measurement connections