![Tektronix DG2020A User Manual Download Page 243](http://html1.mh-extra.com/html/tektronix/dg2020a/dg2020a_user-manual_1077764243.webp)
Appendix B: Performance Verification
BĆ32
DG2020A, P3410, & P3420 User Manual
Characteristics Confirmation Procedure
The following three steps confirm the event input operation.
1. Load the TP5EVENT.PDA test pattern file from the performance check
disk.
2. Press the START/STOP button on the front panel so that the button’s LED
indicator lights.
3. Confirm that a 1
m
s square wave and a 500 ns square wave are displayed on
the oscilloscope alternately for 1 cycle and 2 cycles respectively.
The following four steps confirm the inhibit input operation.
4. Remove the SMB connector connected to the pod CH0 and connect it to
CH2. Next, remove the SMB connector connected to CH1 and connect it to
CH0. Remove the SMB connector connected to EVENT INPUT and
connect it to INHIBIT INPUT.
Figure BĆ26: Inhibit input operation confirmation connections
5. Set the oscilloscope CH1 input impedance to 50
W
.
6. Press the START/STOP button on the front panel twice.
7. Confirm that a square wave with a 1
m
s period is displayed on the oscillo-
scope.
Summary of Contents for DG2020A
Page 2: ...User Manual DG2020A Data Generator With P3410 P3420 Pods 071 0053 50 www tektronix com...
Page 5: ......
Page 15: ...Table of Contents DG2020A P3410 P3420 User Manual...
Page 19: ...Service Safety Summary DG2020A P3410 P3420 User Manual...
Page 50: ...Operating Basics DG2020A P3410 P3420 User Manual 2 15 Figure 2 10 Data structure image...
Page 69: ...Basic Menu Operation DG2020A P3410 P3420 User Manual...
Page 181: ...APPLICATION Menu DG2020A P3410 P3420 User Manual...
Page 211: ...Appendix A Performance Characteristics DG2020A P3410 P3420 User Manual...