![Tektronix DG2020A User Manual Download Page 146](http://html1.mh-extra.com/html/tektronix/dg2020a/dg2020a_user-manual_1077764146.webp)
EDIT Menu
DG2020A, P3410, & P3420 User Manual
3Ć45
Popup Menu.
Figure 3Ć41: Shift register generator popup menu
Table 3-11 describes the parameter items.
Table 3Ć11: Shift register generator parameters
Parameter
Function
Register diagram
Use the 0 and 1 numeric keys to set the register's initialvalue.
Use the "
-
" button to toggle taps.
Register Length
Sets the register length. The register length can be set to a
value between 1 and 32.
Points/Step
The number of data points set for each shift of the register.
Dest Bit
The bit to which the pattern is written
From
When Entered was selected in the Region side menu item,
specifies the first point from which the pattern is written.
Size
When Entered was selected in the Region side menu item,
specifies the number of points into which the pattern is written.