120
LC
: Sets OCP Current
Function:
Sets the OCP current
Format:
LC* *: Set value within range
Range:
Values other than ranges result in parameter errors.
Range varies depending on the total output capacity of the parallel connection.
Model (Type)
Total Output
Capacity
Output Current Ranges (A)
30V Output Type
60V Output Type
500V Output
Type
1000V Output
Type
6kW
2.0 to 220.0
1.0 to 110.0
0.12 to 13.20
0.060 to 6.600
12kW
4.0 to 440.0
2.0 to 220.0
0.24 to 26.40
0.12 to 13.20
18kW
6.0 to 660.0
3.0 to 330.0
0.36 to 39.60
0.18 to 19.80
24kW
8.0 to 880.0
4.0 to 440.0
0.48 to 52.80
0.24 to 26.40
30kW
10.0 to 1100
5.0 to 550.0
0.60 to 66.00
0.30 to 33.00
36kW
12.0 to 1320
6.0 to 660.0
0.72 to 79.20
0.36 to 39.60
42kW
14.0 to 1540
7.0 to 770.0
0.84 to 92.40
0.42 to 46.20
48kW
16.0 to 1760
8.0 to 880.0
1.0 to 105.6
0.48 to 52.80
54kW
18.0 to 1980
9.0 to 990.0
1.1 to 118.8
0.54 to 59.40
60kW
20.0 to 2200
10.0 to 1100
1.1 to 132.0
0.60 to 66.00
66kW
22.0 to 2420
11.0 to 1210
1.3 to 145.2
0.66 to 72.60
72kW
24.0 to 2640
12.0 to 1320
1.4 to 158.4
0.72 to 79.20
78kW
26.0 to 2860
13.0 to 1430
1.6 to 171.6
0.78 to 85.80
84kW
28.0 to 3080
14.0 to 1540
1.7 to 184.8
0.84 to 92.40
90kW
30.0 to 3300
15.0 to 1650
1.8 to 198.0
0.90 to 99.00
96kW
32.0 to 3520
16.0 to 1760
1.9 to 211.2
1.0 to 105.6
102kW
34.0 to 3740
17.0 to 1870
2.0 to 224.4
1.0 to 112.2
108kW
36.0 to 3960
18.0 to 1980
2.2 to 237.6
1.1 to 118.8
114kW
38.0 to 4180
19.0 to 2090
2.3 to 250.8
1.1 to 125.4
120kW
40.0 to 4400
20.0 to 2200
2.4 to 264.0
1.2 to 132.0
<Ex.>
A1,LC44
Summary of Contents for HX-S-01000-12G2
Page 165: ...Special Loads 165 This page is blank...
Page 169: ...Maintenance 169 This page is blank...
Page 211: ...Specifications 211 External Diagrams 1 HX S 030 200G2 F I...
Page 212: ...Specifications 212 2 HX S 030 400G2 F I...
Page 213: ...Specifications 213 3 HX S 060 100G2 F I...
Page 214: ...Specifications 214 4 HX S 060 200G2 F I...
Page 215: ...Specifications 215 5 HX S 0120 50G2 F I...
Page 216: ...Specifications 216 6 HX S 0120 100G2 F I...
Page 217: ...Specifications 217 7 HX S 0400 15G2 F I...
Page 218: ...Specifications 218 8 HX S 0400 30G2 F I...
Page 219: ...Specifications 219 9 HX S 0500 12G2 F I...
Page 220: ...Specifications 220 10 HX S 0500 24G2 F I...
Page 221: ...Specifications 221 11 HX S 01000 6G2 F I...
Page 222: ...Specifications 222 12 HX S 01000 12G2 F I...
Page 223: ...Specifications 223...
Page 239: ......