Controlling with External Analog & Contact Signals
136
External Control Connector Terminal List
Terminal
No.
Signal Name
Terminal
No.
Signal Name
1
Voltage Monitoring Output
14
Common for Analog Signal
2
Current Monitoring Output
15
Common for Analog Signal
3
Output Voltage Control, External Voltage Input
16
Common for Analog Signal
4
Output Voltage Control, External Resistance (B,C)
+ Input
17
Output Voltage Control, External Resistance (B,C) -
Input
5
Output Current Control, External Voltage Input
18
Common for Analog Signal
6
Output Current Control, External Resistance (B,C)
+ Input
19
Output Current Control, External Resistance (B,C) -
Input
7
Output Voltage Control, External Resistance (A)
Input
20
Reference Voltage Output [4.096V]
8
Output Current Control, External Resistance (A)
Input
21
Control Input for Series Operation
9
Output ON/OFF Input
22
Common for Contact Signal
10
TRIP Input
23
Common for Contact Signal
11
Logical Selection Input of TRIP Input
24
Common for Contact Signal
12
Logical Selection Input of LEVEL1_ALM
25
Common for Contact Signal
13
Logical Selection Input of LEVEL2_ALM
26
Common for Contact Signal
I
solated Control Connector Terminal List
Terminal
No.
Signal Name
Without Isolation
OP
With Isolation
OP
1
Isolation, Voltage Monitoring Output
No
Yes
2
Isolation, Common for Voltage/Current Monitoring Output
No
Yes
3
Isolation, Current Monitoring Output
No
Yes
4
Isolation, Output Voltage Control, External Voltage Input
No
Yes
5
Isolation, Output Voltage Control, Common for External Voltage Input
No
Yes
6
Isolation, Output Current Control, External Voltage Input
No
Yes
7
Isolation, Output Current Control, Common for External Voltage Input
No
Yes
8
Isolation, Output ON/OFF Input
No
Yes
9
Isolation, TRIP Input
No
Yes
10
Isolation, Common for Output ON/OFF/TRIP Input
No
Yes
11
LEVEL1_ALM, Status Output/ OUTPUT ON/OFF STS Output
Yes
Yes
12
LEVEL2_ALM, Status Output
Yes
Yes
13
Constant Voltage (CV), Status Output
Yes
Yes
14
Constant Current (CC), Status Output
Yes
Yes
15
Input Voltage, Control Circuit Voltage Monitoring (P-ON), Status Output
Yes
Yes
16
Common for Status Output
Yes
Yes
Uses of Terminals
Output ON/OFF and Input Shutoff with External Contact
Control output voltage/current with external voltage
Control output voltage/current with external resistance
Monitor Output
Status Output
Master-Slave Serie
s Operation
The commons for analog signal (No. 14, No. 15, No. 16, No. 18) and the commons for contact point
signal (No. 22, No. 23, No. 24, No. 25, No. 26) are internally connected with the minus side of the output
terminal.
!
CAUTION
The commons for isolation signal (No. 2, No. 5, No. 7,
No. 10) are common.
!
CAUTION
Summary of Contents for HX-S-01000-12G2
Page 165: ...Special Loads 165 This page is blank...
Page 169: ...Maintenance 169 This page is blank...
Page 211: ...Specifications 211 External Diagrams 1 HX S 030 200G2 F I...
Page 212: ...Specifications 212 2 HX S 030 400G2 F I...
Page 213: ...Specifications 213 3 HX S 060 100G2 F I...
Page 214: ...Specifications 214 4 HX S 060 200G2 F I...
Page 215: ...Specifications 215 5 HX S 0120 50G2 F I...
Page 216: ...Specifications 216 6 HX S 0120 100G2 F I...
Page 217: ...Specifications 217 7 HX S 0400 15G2 F I...
Page 218: ...Specifications 218 8 HX S 0400 30G2 F I...
Page 219: ...Specifications 219 9 HX S 0500 12G2 F I...
Page 220: ...Specifications 220 10 HX S 0500 24G2 F I...
Page 221: ...Specifications 221 11 HX S 01000 6G2 F I...
Page 222: ...Specifications 222 12 HX S 01000 12G2 F I...
Page 223: ...Specifications 223...