Specifications
204
Protection Functions
Specification/Models
30-200
30-400
60-100
60-200
120-50
120-100
Over
Voltage
Protection
Circuit
(OVP)
Range
0.30V-33.00V
0.60V-66.00V
1.2V
-
132.0V
Accuracy
±
(
0.2
%+
5digit
(
0.05V
))
of set value
*11
±
(
0.2
%+
5digit
(
0.5V
))
of set value
*11
Operation
Can select from operations below
• Output OFF by switching stop
• Input switch cut-off (Input switch cut-off turns the power supply’s internal input power relays OFF.)
Over
Current
Protection
Circuit
(OCP)
Range
2.0A-
220.0A
4.0A-
440.0A
1.0A-
110.0A
2.0A-
220.0A
0.5A-
55.00A
1.0A-
110.0A
Accuracy
±
(
0.6
%+
5digit
(
0.5A
)
of
set value
*12
±
(
0.6
%+
10digit
(
1A
)
of
set value
*12
±
(
0.6
%+
5digit
(
0.5A
)
of
set value
*12
±(0.6
%+
10digit(1A)
of
set value
*12
±
(
0.6
%+
5digit
(
50mA
)
of set value
*12
±
(
0.6
%+
5digit
(
500mA
)
of set value
*12
Operation
Can select from operations below
• Output OFF by switching stop
•Input switch cut-off (Input switch cut-off turns the power supply’s internal input power relays OFF.)
Over Heating Protection
Circuit
• Stops switching, shuts off output, and displays alarms if the temperature of the radiating section heat
exceeds 90
C due to stopped fan motor, etc.
• Welds temperature fuses, built in the Inrush Limiting Resistors, at 135
C.
Excessive Input Current
Protection
Fuse
50A
Fuse
100A
Fuse
50A
Fuse
100A
Fuse
50A
Fuse
100A
Specification/Models
400-15
400-30
500-12
500-24
1000-6
1000-12
Over
Voltage
Protection
Circuit
(OVP)
Range
4.0-440.0V
5.0V
-
550.0V
10V-1100V
Accuracy
±
(
0.2
%+
5digit
(
0.5V
))
of set value
*11
±
(
0.2
%+
5digit
(
5V
))
of set value
*11
Operation
Can select from operations below
• Output OFF by switching stop
• Input switch cut-off (Input switch cut-off turns the power supply’s internal input power relays OFF.)
Over
Current
Protection
Circuit
(OCP)
Range
0.15A-
16.50A
0.3A-
33.00A
0.12A-
13.20A
0.24A-
26.40A
0.060A-
6.600A
0.12A-
13.20A
Accuracy
±
(
0.6
%+
5digit
(
50mA
)
of
set value
*12
±
(
0.6
%+
10digit
(
100mA
)
of set
value
*12
±
(
0.6
%+
5digit
(
50mA
)
of
set value
*12
±(0.6
%+
10digit(100mA)
of set value
*12
±
(
0.6
%+
5digit
(
5mA
)
of
set value
*12
±
(
0.6
%+
5digit
(
50mA
)
of set value
*12
Operation
Can select from operations below
• Output OFF by switching stop
•Input switch cut-off (Input switch cut-off turns the power supply’s internal input power relays OFF.)
Over Heating Protection
Circuit
• Stops switching, shuts off output, and displays alarms if the temperature of the radiating section heat
exceeds 90
C due to stopped fan motor, etc.
• Welds temperature fuses, built in the Inrush Limiting Resistors, at 135
C.
Excessive Input Current
Protection
Fuse
50A
Fuse
100A
Fuse
50A
Fuse
100A
Fuse
50A
Fuse
100A
Remote Sensing
• Able to compensate a voltage drop, due to lead wire up to load, of up to 5V one-way.
• Restricts the rise in output voltage within 10mV if sensing lines are opened.
• During remote sensing, the output power can be set to a maximum of 105% of rated output voltage at
the power supply’s output terminals. Also, the output power can be set within the rating.
Summary of Contents for HX-S-01000-12G2
Page 165: ...Special Loads 165 This page is blank...
Page 169: ...Maintenance 169 This page is blank...
Page 211: ...Specifications 211 External Diagrams 1 HX S 030 200G2 F I...
Page 212: ...Specifications 212 2 HX S 030 400G2 F I...
Page 213: ...Specifications 213 3 HX S 060 100G2 F I...
Page 214: ...Specifications 214 4 HX S 060 200G2 F I...
Page 215: ...Specifications 215 5 HX S 0120 50G2 F I...
Page 216: ...Specifications 216 6 HX S 0120 100G2 F I...
Page 217: ...Specifications 217 7 HX S 0400 15G2 F I...
Page 218: ...Specifications 218 8 HX S 0400 30G2 F I...