Using via Digital Data Communication
118
HX-compatible Command Format
All commands and responses are ASCII character strings.
Characters "A" to "Z" are recognized as command strings and characters "+", "-", ".", and "0" to"9" are recognized as
parameters.
HX-compatible Command Group Sending
Multiple commands can be sent in a single string by separating commands with ",".
<Ex.>A1,MV10.00,MC2.00,OT1
However, a single string with multiple commands assigning addresses will error.
<Ex.>A1,OT1,A2,OT1 /* Error due to multiple address assignment commands */
Alarm Response Trigger Factors of HX-compatible Commands
In the event that any of the following error conditions are met, the HX-S-G2 power supply will promptly return an
alarm response "ALM128".
If an error is generated while inputting commands, recovery will not occur until delimiter is received.
To prevent this, make certain to send either "CR, LF, or CR+LF" when an alarm response is received.
When undefined command is received
When command parameters exceed the range
When a character or symbol other than numerals 0~9, +, -, and decimal point is sent in parameters
When sent with a single p
arameter containing more than 2 decimal points
When sent with spaces between the command and parameter
<Ex.>MV_35
Space
When a command is sent in lowercase
<Ex.>mv35
When a string received at one time (until delimiter is received) exceeds 128 cha
racters
Setting examples that are not errors
Throw away digits in parameters which exceed the maximum number of numerical places
<Ex> MV100.99
MV100.9
For HX-S-G2 Series power supplies, if either OVP, OCP or OHP error is generated, the alarm response will
change to "ALM160". During device errors, only "LV", "LC", "AR", "TP", and "TK" commands are valid. All other
commands will return alarm responses.
Delimiter of HX-compatible Command
Please add an end character (delimiter) to the end of commands being sent to the HX-S-G2 power supply.
Possible delimiters that can be used are listed below.
CR Carriage Return
LF Line Feed
CR+LF
Use any of the above as a delimiter.
Summary of Contents for HX-S-01000-12G2
Page 165: ...Special Loads 165 This page is blank...
Page 169: ...Maintenance 169 This page is blank...
Page 211: ...Specifications 211 External Diagrams 1 HX S 030 200G2 F I...
Page 212: ...Specifications 212 2 HX S 030 400G2 F I...
Page 213: ...Specifications 213 3 HX S 060 100G2 F I...
Page 214: ...Specifications 214 4 HX S 060 200G2 F I...
Page 215: ...Specifications 215 5 HX S 0120 50G2 F I...
Page 216: ...Specifications 216 6 HX S 0120 100G2 F I...
Page 217: ...Specifications 217 7 HX S 0400 15G2 F I...
Page 218: ...Specifications 218 8 HX S 0400 30G2 F I...
Page 219: ...Specifications 219 9 HX S 0500 12G2 F I...
Page 220: ...Specifications 220 10 HX S 0500 24G2 F I...
Page 221: ...Specifications 221 11 HX S 01000 6G2 F I...
Page 222: ...Specifications 222 12 HX S 01000 12G2 F I...
Page 223: ...Specifications 223...