Basic Usage
32
Remote Sensing
Remote sensing is used for solving problems with voltage drop between the output terminal and load due to wiring
by compensating for the voltage drop. Remote sensing is able to compensate voltages up to 5V
per direction (one-
way).
Wire as shown in the diagram below.
* Crimping terminal to connect to a remote sense terminal, please use the crimp terminal with an isolation coating.
* The figure above is an example of connecting HX-S-0500-12G2.
C1: Electrolytic Capacitor 100 to 1000 μF
(Low Impedance Item)
C2: Film Capacitor 1 to 10 μ
F
Connect when wishing to lower output
ripple/noise from the load terminal.
MEMO
Turn POWER switch OFF before wiring to the output terminal.
!
DANGER
●
While using remote sensing, do not switch output lines using switches, etc.
Doing so may lead to damaging the power supply..
● Because the output terminal’s voltage is detected by the OVP circuit, please
set the voltage value of the OVP to include the voltage drop amount (round
trip) of the wires outputting the voltage you wish to protect.
!
CAUTION
Load
+
-
C1
C2
If you want to ground it is done at the
load end.
Wiring
material
Do wiring material
twisting,Route as close as
much as possible.
M5 Screw
M5 Crimping
terminal
Output Terminal
Cover
M3 Screw
HX30-200/60V/120V Type
Remot e sense terminal
『
+
』
(M3 Screw)
Remot e sense terminal
『
+
』(
Accessory
connector
)
HX30-400 Type
HX400V/500V Type
HX1000V Type
Remot e sense terminal
『
+
』
(M3 Screw)
Remot e sense terminal
『-』
(M3 Screw)
Remot e sense terminal
『-』
(M3 Screw)
Remot e sense terminal
『-』(
Accessory
connector
)
Remot e sense terminal
『
+
』(
Accessory
connector
)
Remot e sense terminal
『-』(
Accessory
connector
)
Summary of Contents for HX-S-01000-12G2
Page 165: ...Special Loads 165 This page is blank...
Page 169: ...Maintenance 169 This page is blank...
Page 211: ...Specifications 211 External Diagrams 1 HX S 030 200G2 F I...
Page 212: ...Specifications 212 2 HX S 030 400G2 F I...
Page 213: ...Specifications 213 3 HX S 060 100G2 F I...
Page 214: ...Specifications 214 4 HX S 060 200G2 F I...
Page 215: ...Specifications 215 5 HX S 0120 50G2 F I...
Page 216: ...Specifications 216 6 HX S 0120 100G2 F I...
Page 217: ...Specifications 217 7 HX S 0400 15G2 F I...
Page 218: ...Specifications 218 8 HX S 0400 30G2 F I...
Page 219: ...Specifications 219 9 HX S 0500 12G2 F I...
Page 220: ...Specifications 220 10 HX S 0500 24G2 F I...
Page 221: ...Specifications 221 11 HX S 01000 6G2 F I...
Page 222: ...Specifications 222 12 HX S 01000 12G2 F I...
Page 223: ...Specifications 223...
Page 239: ......