Controlling with External Analog & Contact Signals
144
TRIP Operation with Isolated External Contacts
* This function can be set for isolation-option-featured type "model name with I" only.
The input for this machine can be shut off (switching stop by setting) using output from small capacity contacts or
photocouplers.
Use a photocoupler or a small signal relay or switch with a minimum contact capacity of 5V, 2.5mA.
Connecting
Wire the cables to the isolated control connector (accessory) terminals No. 9 and 10.
By connecting the external control connector (accessory) terminals No. 11 and 24, contact-b operation can be
performed.
TRIP operation with insulation external contacts
11
24
9
10
a Case of contact a operation selection (external control connector
No.11, No.24 not connected)
Closed: TRIP
b Case of contact a operation selection (external control connector
No.11, No.24 connected)
open: TRIP
Insulation Control Connector
Photocupler or Contact
Twisted-Pair Wire
External Control Connector
You can choose TRIP operation by short circuit (make) of contact a and TRIP
operation by opening (break) of contact b.
MEMO
Not suited for power contacts such as main contacts for
electromagnetic contactors or power relays.
!
CAUTION
The commons for contact point signal (external control connector No. 24) is internally
connected to the minus side of the output terminal.
Isolation for the wire connecting to the external control should be more than the relative ground
voltage of this product.
Otherwise, the user may receive electric shock.
!
CAUTION
Summary of Contents for HX-S-01000-12G2
Page 165: ...Special Loads 165 This page is blank...
Page 169: ...Maintenance 169 This page is blank...
Page 211: ...Specifications 211 External Diagrams 1 HX S 030 200G2 F I...
Page 212: ...Specifications 212 2 HX S 030 400G2 F I...
Page 213: ...Specifications 213 3 HX S 060 100G2 F I...
Page 214: ...Specifications 214 4 HX S 060 200G2 F I...
Page 215: ...Specifications 215 5 HX S 0120 50G2 F I...
Page 216: ...Specifications 216 6 HX S 0120 100G2 F I...
Page 217: ...Specifications 217 7 HX S 0400 15G2 F I...
Page 218: ...Specifications 218 8 HX S 0400 30G2 F I...
Page 219: ...Specifications 219 9 HX S 0500 12G2 F I...
Page 220: ...Specifications 220 10 HX S 0500 24G2 F I...
Page 221: ...Specifications 221 11 HX S 01000 6G2 F I...
Page 222: ...Specifications 222 12 HX S 01000 12G2 F I...
Page 223: ...Specifications 223...
Page 239: ......