D. Request” mode
Request to speak when the microphone On/Off key is
pressed (default 100 microphones at most, set up the
request microphone number limit at DCS or web
control ).
a. The chairman unit can approve or reject his/her
speak;
b. When his/her request is approved, he/she can
speak and the last activated microphone will be
turn off at the same time.
E. “PTT” mode
Active microphone number limitation (1~8)
NOT
reached:
a. The microphone will be activated when the
microphone On/Off key is pressed and held,
the speaker can give his/her speech;
b. The microphone will be deactivated when the
microphone On/Off key is released.
Active microphone number limitation (1~8)
reached
:
Pressing the microphone On/Off key cannot
activate the microphone until one of the activated
microphones is switched off.
A camera can focus an activated microphone
automatically (camera position preset by application
software). Speaker’s video can be exported to and
displayed on large screen(s).
3. Sign-in
(application software needed)
To carry out voting, congress units with voting function
should be registered. With application software,
registration is available by choosing “Seat Sign-in”.
Key press sign-in
In sign-in status, “Please sign-in” will be displayed on
the LCD, click “Please sign-in” button or “1” to sign-in,
as in the following figure:
If "Allow belated sign-in after stop" is enabled, when
sign-in process is completed, “Belated sign-in" will be
displayed on the LCD. The "Belated sign-in" button can
now be clicked for belated sign-in. Or else, after stop of
sign-in, “Not present.” will be displayed on the LCD.
PIN code sign-in
In PIN code sign-in status, the LCD will display as the
following figure:
Input PIN code through virtual keyboard to sign in. If
the PIN code is wrong, "Invalid PIN code" will be
displayed on the LCD.
4. Voting
(for units with function)
Voting can be originated by TAIDEN conference
management system software, support/approve/
Yes/No/Abstain or Yes/No and other voting method.
The voting option will be displayed on LCD, click
on the option button to vote;
Note:
Active microphone number(1~8) setting is only
effective to congress unit. The maximum
capacity is 8 units (including chairman unit and
VIP unit).
After CMU connect to the DCS and meeting
started, swipe the screen to view speaking list.
73
Summary of Contents for HCS-4800 Series
Page 55: ...Figure Microphone Test interface 41...
Page 82: ...Figure 3 3 8 Dual backup microphone high end congress system solution 69...
Page 84: ...Setting brightness Setting language Setting unit information 71...
Page 100: ...Figure 3 5 6 Installation diagram of HCS 48U6SPK 87...
Page 112: ...Figure 3 6 3 Cutout of HCS 48U7M 80 flush mounted congress unit unit mm 99...
Page 115: ...Figure 3 6 7 Disassembly caution of HCS 48U9 series flush mounted congress unit 102...
Page 125: ...3 7 2 Installation Figure 3 7 2 Cutout of HCS 48U10 80 series congress unit unit mm 112...
Page 126: ...Figure 3 7 3 Installation of HCS 48U10 80 series congress unit 113...
Page 167: ...3 13 2 Installation Figure 3 13 2 Cutout of HCS 4857 series congress unit unit mm 150...
Page 172: ...4 1 Functions and indications Front Side Bottom Figure 4 1 HCS 8685 Interpreter unit 154...