According to the requirements of the specific case in this
section, the configuration is as the following:
1. Configuration CMU
a)
Active microphone number limitation:
active
microphone number limitation limited to 2 implies
that at most two microphones can be turned on.
Chairman unit and VIP are not restricted and do not
count in this limitation.
b)
Speech mode:
speech mode is set to “Open”, none
other delegate can turn on his/her microphone if
the current speaker does not turn off his/her
microphone.
c)
Simultaneous interpretation - language channel
configuration:
Assuming that three languages are
used by the delegates, including Chinese, English
and French, meaning that three kinds of language
channels are needed, respectively, set channel
1–Chinese, channel 2-English and channel
3-French.
d)
Simultaneous interpretation – booth number
configuration:
The booth number is set as 2.
Translation between English-Chinese and
French-Chinese respectively.
e)
Simultaneous interpretation - output channel
configuration:
The output channel A of booth 1 is
English, output channel C is “No output” and output
channel B is “All channels”, and two Interpreter
units are equipped. The output channel A of booth
2 is French, output channel B and C is “No output”,
and two Interpreter units are equipped.
f)
Simultaneous interpretation – auto-relay booth
configuration:
booth #1: no auto-relay booth
booth #2: set auto relay booth number as 1,
meaning that booth #1 is the auto-relay booth
for booth #2. When booth #1 uses output
channel B, booth #2 will go to auto-relay
status automatically and auto-relay
interpretation will be achieved.
g) Chairman priority mode is set as “All mute”.
2. Configurate Interpreter units in booth 1 (the
configuration of both Interpreter units is the same)
a) Channel B output: pressing output channel B switch
and rotating Primary knob at the same time, and set
Chinese as channel B output language.
b) Booth number is set to 1.
c) Preset monitoring channel. Channel a, b, c are set
as 1-Chinese, 2-English and 3-French respectively.
3. Configurate Interpreter units in booth 2 (the
configuration of both Interpreter units is the same)
a) Channel B output does not need to be setup
(because output channel B of booth 2 is set as “No
output” in CMU configuration).
b) Booth number is set to 2.
c) Preset monitoring channel. Channel a, b, c are set
as 1-Chinese, 2-English and 3-French respectively.
4. Volume control
Turn on delegate/chairman unit and adjust the volume of
the built-in loudspeaker on the congress units to suitable
volume.
5. Finish configuration, and the system can work
now.
173
Summary of Contents for HCS-4800 Series
Page 55: ...Figure Microphone Test interface 41...
Page 82: ...Figure 3 3 8 Dual backup microphone high end congress system solution 69...
Page 84: ...Setting brightness Setting language Setting unit information 71...
Page 100: ...Figure 3 5 6 Installation diagram of HCS 48U6SPK 87...
Page 112: ...Figure 3 6 3 Cutout of HCS 48U7M 80 flush mounted congress unit unit mm 99...
Page 115: ...Figure 3 6 7 Disassembly caution of HCS 48U9 series flush mounted congress unit 102...
Page 125: ...3 7 2 Installation Figure 3 7 2 Cutout of HCS 48U10 80 series congress unit unit mm 112...
Page 126: ...Figure 3 7 3 Installation of HCS 48U10 80 series congress unit 113...
Page 167: ...3 13 2 Installation Figure 3 13 2 Cutout of HCS 4857 series congress unit unit mm 150...
Page 172: ...4 1 Functions and indications Front Side Bottom Figure 4 1 HCS 8685 Interpreter unit 154...
Page 232: ...Appendix Custom made cable 211...