3.5.3 Connection
3.5.3.1 Connecting to the CMU or the EMU
The HCS-48U6 series (HCS-48U6MICM/80 and
HCS-48U6SELM/80) congress unit is equipped with
two RJ45 sockets supports daisy chain connection via
cat5e cable. When connecting the CMU to the
contribution units, the CBL8P2RJ45 converter cable is
needed to connect the first unit to the socket of the
CMU.
One HCS-48U6MICM/80 discussion unit can be
connected to one HCS-48U6DVOT voting unit and
one HCS-48U6SPK loudspeaker;
One HCS-48U6SELM/80 channel selector can be
connected to one HCS-48U6MICS discussion unit,
one HCS-48U6DVOT voting unit and one
HCS-48U6SPK loudspeaker.
Figure 3.5.8 HCS-48U6 series congress unit connected
to the CMU/EMU
For a longer distance between the contribution unit and
the CMU/EMU, a Cat5e cable can be used. One end of
the Cat5e cable is connected to output of the main unit
via the CBL8P2RJ45S converter cable; the other end
of the Cat5e cable is connected to the contribution unit.
Figure 3.5.9 HCS-48U6 series congress unit connected
to the CMU/EMU
Neither the replacement of congress units nor cable
faults between congress units will affect the other units
if “Closed Loop - Daisy Chain” connection topology is
selected. “Closed Loop - Daisy Chain” connection,
achieved by closing the loop of the daisy-chained units,
increases system reliability. For “Closed Loop - Daisy
Chain” ring connection, HCS-8600MCLS Loop switcher
is needed. The "TO MU" port of HCS-8600MCLS is
connected to the output of the main unit via
CBL8P2RJ45 converter cable; the other port of
HCS-8600MCLS is connected to the contribution unit;
at last, connect the last contribution unit back to the
CMU via a CBL8P2RJ45S converter cable.
Figure 3.5.10 “Closed Loop - Daisy Chain” connection
between the CMU and HCS-48U6 series congress unit
3.5.3.2 Connections between congress units
HCS-48U6MICM/80 and HCS-48U6SELM/80 congress
units are daisy-chained easily and conveniently by
dedicated Cat5e cables.
When connecting to another congress unit, just use the
Cat5e cable of the unit to another RJ45 socket of the
next unit.
Figure 3.5.11 “Daisy-chain” connection between
HCS-48U6/80 series congress units
89
Summary of Contents for HCS-4800 Series
Page 55: ...Figure Microphone Test interface 41...
Page 82: ...Figure 3 3 8 Dual backup microphone high end congress system solution 69...
Page 84: ...Setting brightness Setting language Setting unit information 71...
Page 100: ...Figure 3 5 6 Installation diagram of HCS 48U6SPK 87...
Page 112: ...Figure 3 6 3 Cutout of HCS 48U7M 80 flush mounted congress unit unit mm 99...
Page 115: ...Figure 3 6 7 Disassembly caution of HCS 48U9 series flush mounted congress unit 102...
Page 125: ...3 7 2 Installation Figure 3 7 2 Cutout of HCS 48U10 80 series congress unit unit mm 112...
Page 126: ...Figure 3 7 3 Installation of HCS 48U10 80 series congress unit 113...
Page 167: ...3 13 2 Installation Figure 3 13 2 Cutout of HCS 4857 series congress unit unit mm 150...
Page 172: ...4 1 Functions and indications Front Side Bottom Figure 4 1 HCS 8685 Interpreter unit 154...
Page 232: ...Appendix Custom made cable 211...