2.1.2 Connection
2.1.2.1 To contribution units
HCS-4800 series CMU has 2 outlet (8P-DIN) trunk-line
cable sockets for connecting to contribution units.
TAIDEN full digital congress unit has two types of
connection interface, a) equipped with two cables with
standard 8P-DIN connectors; or b) equipped with two
RJ45 sockets for daisy
chain
connection
(recommended use of cat5e cable with a drain wire &
RJ45 plug with metal shield).
The contribution units are equipped with a cable with a
standard 8P-DIN male connector. When connecting the
CMU to the contribution units, just connect the male
connector of the first unit to the socket of the CMU.
Figure 2.1.2 CMU connecting to contribution units
(8P-DIN)
For a longer distance between the contribution unit and
the CMU/EMU, a CBL8PS extension cable can be
used. One end of this cable is equipped with a 8P-DIN
male connector, the opposite end is equipped with a
female connector. Just connect the female connector of
the cable to the contribution unit, and connect the male
connector to the output of the main unit. The Cat5e
cable can also be used as an extension cable, one end
of the Cat5e cable is connected to output of the main
unit via the CBL8P2RJ45S converter cable; the other
end of the Cat5e cable is connected to the 8P-DIN
male connector of the contribution unit via the
CBL8S2RJ45S converter cable.
Figure 2.1.3 CMU connecting to contribution units
(8P-DIN)
For “Closed Loop - Daisy Chain” ring connection,
HCS-8600MCLS Loop switcher is needed. The "TO
MU" port of HCS-8600MCLS is connected to the output
of the main unit via CBL8P2RJ45 converter cable; the
other port of HCS-8600MCLS is connected to the
contribution unit via CBL8P2RJ45 converter cable; at
last, connect the last contribution unit back to the CMU
via a CBL8PS extension cable.
Figure 2.1.4 “Closed Loop - Daisy Chain” connection
topology (8P-DIN)
Contribution unit equipped with two RJ45 sockets
supports daisy chain connection via cat5e cable. When
connecting the CMU to the contribution units, the
CBL8P2RJ45 converter cable is needed to connect the
first unit to the socket of the CMU.
12
Summary of Contents for HCS-4800 Series
Page 55: ...Figure Microphone Test interface 41...
Page 82: ...Figure 3 3 8 Dual backup microphone high end congress system solution 69...
Page 84: ...Setting brightness Setting language Setting unit information 71...
Page 100: ...Figure 3 5 6 Installation diagram of HCS 48U6SPK 87...
Page 112: ...Figure 3 6 3 Cutout of HCS 48U7M 80 flush mounted congress unit unit mm 99...
Page 115: ...Figure 3 6 7 Disassembly caution of HCS 48U9 series flush mounted congress unit 102...
Page 125: ...3 7 2 Installation Figure 3 7 2 Cutout of HCS 48U10 80 series congress unit unit mm 112...
Page 126: ...Figure 3 7 3 Installation of HCS 48U10 80 series congress unit 113...
Page 167: ...3 13 2 Installation Figure 3 13 2 Cutout of HCS 4857 series congress unit unit mm 150...
Page 172: ...4 1 Functions and indications Front Side Bottom Figure 4 1 HCS 8685 Interpreter unit 154...
Page 232: ...Appendix Custom made cable 211...