System Test
TAIDEN conference system provides the facility for system testing to find out the problems of units accurately. This
facility aims to find out and solve the problems prior to a conference to ensure the reliability of the entire conference
system.
The System Test consists of Key Test, Microphone Test, SI Channel Test and LED Test.
Key Test
The procedure of key test:
1. Click the “Start Test” button to begin;
2. All contribution units enter the key test state. To perform the key test, the operator shall press the keys on each
contribution unit following the indicator prompt;
3. When all keys are pressed, click the “Stop Test” button to stop;
4. The result of the test is shown in the left textbox.
Figure: Key Test interface
Mic. Test
Test the microphone of the units connected to the conference main unit, and the interface of the following figure is
displayed:
To begin the test, the user shall first set the test time for each microphone in “Mic. Test Time (00:00:00, HH:MM:SS)”,
select “Play Sound” or not (play white noise to assist testing), then click the “Start Test” button to begin. If the current
microphone is in good condition, it will be activated, and its number is shown in the “Current Microphone ID” textbox. The
remaining test time will also be shown under the textbox. The system is testing the microphones according to the
microphone IDs, in ascending order.
Note:
If the priority key is pressed, the microphone is unable to be tested .
41
Summary of Contents for HCS-4800 Series
Page 55: ...Figure Microphone Test interface 41...
Page 82: ...Figure 3 3 8 Dual backup microphone high end congress system solution 69...
Page 84: ...Setting brightness Setting language Setting unit information 71...
Page 100: ...Figure 3 5 6 Installation diagram of HCS 48U6SPK 87...
Page 112: ...Figure 3 6 3 Cutout of HCS 48U7M 80 flush mounted congress unit unit mm 99...
Page 115: ...Figure 3 6 7 Disassembly caution of HCS 48U9 series flush mounted congress unit 102...
Page 125: ...3 7 2 Installation Figure 3 7 2 Cutout of HCS 48U10 80 series congress unit unit mm 112...
Page 126: ...Figure 3 7 3 Installation of HCS 48U10 80 series congress unit 113...
Page 167: ...3 13 2 Installation Figure 3 13 2 Cutout of HCS 4857 series congress unit unit mm 150...
Page 172: ...4 1 Functions and indications Front Side Bottom Figure 4 1 HCS 8685 Interpreter unit 154...
Page 232: ...Appendix Custom made cable 211...