Figure 2.1.5 CMU connecting to contribution units
(RJ45)
For a longer distance between the contribution unit and
the CMU/EMU, a Cat5e cable can be used. One end of
the Cat5e cable is connected to output of the main unit
via the CBL8P2RJ45S converter cable; the other end
of the Cat5e cable is connected to the contribution unit.
Figure 2.1.6 CMU connecting to contribution units
(RJ45)
For “Closed Loop - Daisy Chain” ring connection,
HCS-8600MCLS Loop switcher is needed. The "TO
MU" port of HCS-8600MCLS is connected to the output
of the main unit via CBL8P2RJ45 converter cable; the
other port of HCS-8600MCLS is connected to the
contribution unit; at last, connect the last contribution
unit back to the CMU via a CBL8P2RJ45S converter
cable.
Figure 2.1.7 “Closed Loop - Daisy Chain” connection
topology (RJ45)
In HCS-4800 series fully digital congress system,
power is provided by HCS-4800M CMU (or HCS-8600
EMU) for all congress units. Since the power capacity
of a 8P-DIN interface is limited, it must be ensured that,
during the installation, the sum of the total power
consumption of all the congress units connected to
every single 8P-DIN interface plus the power loss in the
extension cables does not surpass the power limit of
each 6P-DIN interface. Otherwise the system will not
work properly or automatic protection will occur. (refer
2.1.2.2 To sound equipment
The CMU of the HCS-4800 system has a pair of RCA
symmetrical audio outputs “LINE OUT 2” and a 3-cord
XLR balanced output “LINE OUT 1”, to be connected to
a PA. Connecting the RCA symmetrical audio outputs
or the 3-cord XLR balanced output of the CMU to the
input port of the PA via an audio wire.
Figure 2.1.8 CMU connecting to PA
13
Summary of Contents for HCS-4800 Series
Page 55: ...Figure Microphone Test interface 41...
Page 82: ...Figure 3 3 8 Dual backup microphone high end congress system solution 69...
Page 84: ...Setting brightness Setting language Setting unit information 71...
Page 100: ...Figure 3 5 6 Installation diagram of HCS 48U6SPK 87...
Page 112: ...Figure 3 6 3 Cutout of HCS 48U7M 80 flush mounted congress unit unit mm 99...
Page 115: ...Figure 3 6 7 Disassembly caution of HCS 48U9 series flush mounted congress unit 102...
Page 125: ...3 7 2 Installation Figure 3 7 2 Cutout of HCS 48U10 80 series congress unit unit mm 112...
Page 126: ...Figure 3 7 3 Installation of HCS 48U10 80 series congress unit 113...
Page 167: ...3 13 2 Installation Figure 3 13 2 Cutout of HCS 4857 series congress unit unit mm 150...
Page 172: ...4 1 Functions and indications Front Side Bottom Figure 4 1 HCS 8685 Interpreter unit 154...
Page 232: ...Appendix Custom made cable 211...