4.2 Connection
4.2.1 Connecting to the CMU or the EMU
HCS-8685 interpreter unit is equipped with a cable with a
standard 8P-DIN male connector. When connecting the
CMU to the contribution units, just connect the male
connector of the first unit to the socket of the CMU.
Figure 4.3 HCS-8685 Interpreter unit connected to the
CMU or the EMU
For a longer distance between the interpreter unit and
the CMU/EMU, a CBL8PS extension cable can be used.
One end of this cable is equipped with a 8P-DIN male
connector, the opposite end is equipped with a female
connector. Just connect the female connector of the
cable to the interpreter unit, and connect the male
connector to the output of the main unit. The Cat5e cable
can also be used as an extension cable, one end of the
Cat5e cable is connected to output of the main unit via
the CBL8P2RJ45S converter cable; the other end of the
Cat5e cable is connected to the 8P-DIN male connector
of the interpreter unit via the CBL8S2RJ45S converter
cable.
Figure 4.4 HCS-8685 Interpreter unit connected to the
CMU or the EMU
For “Closed Loop - Daisy Chain” ring connection,
HCS-8600MCLS Loop switcher is needed. The "TO MU"
port of HCS-8600MCLS is connected to the output of the
main unit via CBL8P2RJ45 converter cable; the other
port of HCS-8600MCLS is connected to the interpreter
unit via CBL8P2RJ45 converter cable; at last, connect
the last interpreter unit back to the CMU via a CBL8PS
extension cable.
Figure 4.5 “Closed Loop - Daisy Chain” connection
topology
4.2.2 Connection between Interpreter units
All HCS-8685 units are daisy-chained easily and
conveniently by dedicated 6-pin cables.
When connecting to another unit, just connect the
8P-DIN standard female connector on the cable of the
unit to the 8P-DIN standard male connector on the cable
of the next unit.
157
Summary of Contents for HCS-4800 Series
Page 55: ...Figure Microphone Test interface 41...
Page 82: ...Figure 3 3 8 Dual backup microphone high end congress system solution 69...
Page 84: ...Setting brightness Setting language Setting unit information 71...
Page 100: ...Figure 3 5 6 Installation diagram of HCS 48U6SPK 87...
Page 112: ...Figure 3 6 3 Cutout of HCS 48U7M 80 flush mounted congress unit unit mm 99...
Page 115: ...Figure 3 6 7 Disassembly caution of HCS 48U9 series flush mounted congress unit 102...
Page 125: ...3 7 2 Installation Figure 3 7 2 Cutout of HCS 48U10 80 series congress unit unit mm 112...
Page 126: ...Figure 3 7 3 Installation of HCS 48U10 80 series congress unit 113...
Page 167: ...3 13 2 Installation Figure 3 13 2 Cutout of HCS 4857 series congress unit unit mm 150...
Page 172: ...4 1 Functions and indications Front Side Bottom Figure 4 1 HCS 8685 Interpreter unit 154...
Page 232: ...Appendix Custom made cable 211...