![Taiden HCS-4800 Series Installation And Operating Manual Download Page 185](http://html1.mh-extra.com/html/taiden/hcs-4800-series/hcs-4800-series_installation-and-operating-manual_3394946185.webp)
Chapter 5 System connection and basic setup procedure
5.1 System connection
HCS-4800 series fully digital congress system has a
simple and reasonable structure with high extendibility in
hardware. The system installation is simple and quick
and does not need special training. Daisy-chain
connection is adopted between congress units as well as
to CMU via dedicated 8-pin cable or converter cable.
TCP/IP protocol is adopted for Ethernet connection
between CMU and PC. As a result remote control,
remote diagnosis and remote update can be achieved.
Application software for client and server can run on one
computer or on different computers in the same LAN.
The operator is able to control the progress of the
meeting flexibly.
In this chapter, the connections of HCS-4800 series fully
digital congress system are introduced by diagrams and
examples.
5.1.1 Connection principles
In HCS-4800 series fully digital congress system, power
is provided by HCS-4800M or HCS-8600MEA or
HCS-8600EMS for all congress units. Thus, the total
number of system units in any installation is limited by
the maximum power handling capacity and control
capacity of the HCS-4800M or HCS-8600MEA or
HCS-8600EMS. It must be ensured that, during the
installation, the sum of the total power consumption of all
the congress units connected to every single 8P-DIN
interface plus the power loss in the extension cables
does not surpass the power limit of each 8P-DIN
interface. Otherwise the system will not work properly or
automatic protection will occur. Refer to table 5.1.1 for
maximum load capability.
By cascade connecting extension main units
(HCS-8600MEA series) or extension units
(HCS-8600MES),
the
HCS-8600
system can
accommodate 4096 discussion/voting units (by using
system application software up to 100 chairman units
can be connected but only 1 chairman unit has control
facilities), 378 interpreter units (63 interpreter booths, 6
in each), an unlimited quantity of channel selectors, and
provide 64 language channels (including floor language)
simultaneous interpretation.
Note:
The added up cable lengths between a main unit
and the most remote congress unit must not exceed
250 m;
The length of an individual extension cable must not
exceed 80 meters. Otherwise it will affect the signal
quality. In case the length exceeds 80 m,
HCS-4852T(N) is needed; The length of an
individual extension cable following HCS-4852T(N)
must not exceed 80 meters;
When the extension cable is longer than 60 meters,
please be sure to replace the cat5e cable with
braided shield;
The extension cable between the main
unit/extension unit and the first congress unit is
carrying the maximum possible current. However,
the cable length between the two last congress
units is nearly insignificant because this cable only
carries the current for one unit.
167
Summary of Contents for HCS-4800 Series
Page 55: ...Figure Microphone Test interface 41...
Page 82: ...Figure 3 3 8 Dual backup microphone high end congress system solution 69...
Page 84: ...Setting brightness Setting language Setting unit information 71...
Page 100: ...Figure 3 5 6 Installation diagram of HCS 48U6SPK 87...
Page 112: ...Figure 3 6 3 Cutout of HCS 48U7M 80 flush mounted congress unit unit mm 99...
Page 115: ...Figure 3 6 7 Disassembly caution of HCS 48U9 series flush mounted congress unit 102...
Page 125: ...3 7 2 Installation Figure 3 7 2 Cutout of HCS 48U10 80 series congress unit unit mm 112...
Page 126: ...Figure 3 7 3 Installation of HCS 48U10 80 series congress unit 113...
Page 167: ...3 13 2 Installation Figure 3 13 2 Cutout of HCS 4857 series congress unit unit mm 150...
Page 172: ...4 1 Functions and indications Front Side Bottom Figure 4 1 HCS 8685 Interpreter unit 154...
Page 232: ...Appendix Custom made cable 211...