3.10.4 Operation
Before a meeting starts, the congress units need to be
configured by the operator, including: numbering and
testing.Then
introduce
the operation of
HCS-4841DMIC multifunction connector.
1. Number
First of all, make sure that all the multifunction
connector are connected properly to the CMU. All
connector must be numbered when the system is used
for the first time or when adding or replacing congress
units. The numbering function can be activated by
application software or the main unit.
2. Speaking
(without software)
Speaking mode is configured on the CMU (refer to
section 2.1.3).
A. “Open” mode
Active microphone number limitation (1~8)
NOT
reached
:
a. The microphone will be activated when the
microphone On/Off key is pressed
, t
he speaker
can give his/her speech
;
b. The microphone will be deactivated when the
microphone On/Off key is pressed again.
Active microphone number limitation (1~8)
reached
:
a. Press
the microphone On/Off key to request to
speak;
b. Press the microphone On/Off key again to cancel
the request to speak;
c. When an active microphone is turned off, the first
request microphone will be activated.
B
.
“Override” mode
■ Active microphone number limitation (1~8)
NOT
reached
:
a. The microphone will be activated when the
microphone On/Off key is pressed
, t
he speaker
can give his/her speech
;
b. The microphone will be deactivated when the
microphone On/Off key is pressed again.
Active microphone number limitation (1~8)
reached
:
If the delegate microphone On/Off key is pressed,
its microphone will be activated and the first
activated delegate microphone will be deactivated
at the same time to maintain the active
microphone number limitation. If the number of
active microphone (including chairman and VIP
unit) reaches 8, turning on another microphone will
switch off the delegate microphone which turned
on first.
C. “Voice” mode
Active microphone number limitation (1~8)
NOT
reached
:
a. The microphone On/Off key indicating light
remains on. When the delegate speaks into the
microphone at a short distance, the microphone
will be activated;
b. If the delegate does not speak for several
seconds, the microphone will be deactivated
automatically. The interval time can be adjusted
at the main unit (refer to section 2.1.3);
c. When the microphone is activated, it can be
turned off by pressing the microphone On/Off
key.
Active microphone number limitation (1~8)
reached
:
All other microphones cannot be activated unless
one of the active microphone
s
is turned off.
D. “Request” mode
a. Request to speak when the microphone On/Off
key is pressed (default 100 microphones at most,
set up the request microphone number limit at
DCS or web control ). The chairman unit can
approve or reject his/her speak;
Note:
When numbering, please number the congress
units
one by one and do NOT press the
microphone On/Off button of several congress
units at the same time.
135
Summary of Contents for HCS-4800 Series
Page 55: ...Figure Microphone Test interface 41...
Page 82: ...Figure 3 3 8 Dual backup microphone high end congress system solution 69...
Page 84: ...Setting brightness Setting language Setting unit information 71...
Page 100: ...Figure 3 5 6 Installation diagram of HCS 48U6SPK 87...
Page 112: ...Figure 3 6 3 Cutout of HCS 48U7M 80 flush mounted congress unit unit mm 99...
Page 115: ...Figure 3 6 7 Disassembly caution of HCS 48U9 series flush mounted congress unit 102...
Page 125: ...3 7 2 Installation Figure 3 7 2 Cutout of HCS 48U10 80 series congress unit unit mm 112...
Page 126: ...Figure 3 7 3 Installation of HCS 48U10 80 series congress unit 113...
Page 167: ...3 13 2 Installation Figure 3 13 2 Cutout of HCS 4857 series congress unit unit mm 150...
Page 172: ...4 1 Functions and indications Front Side Bottom Figure 4 1 HCS 8685 Interpreter unit 154...
Page 232: ...Appendix Custom made cable 211...