CAUTION: Unplug the vacuum cleaner before servicing
1. Access the motor compartment as shown on pages 38-39.
2. Remove the clean air motor and disconnect the black and white leads (Fig. A.) NOTE: The yellow
wire from the clean air motor is not used.
3. Remove the two screws holding the thermal reset (Fig. B.)
4. Place one lead on each side of the thermal reset and check for continutity through it (Fig. C and D.)
5. If there is no continunity replace the thermal reset or the wire harness. See page 50 for instructions. If
the thermal is good proceed to the next step.
III. Troubleshooting
D. Machine Will Not Power on Section 5: Check Thermal Reset