2.8. Expansion Enclosure Support
Monitoring:
A managing RAID system is aware of the status of JBOD components including
those of:
Expander controller (presence, voltage and thermal readings)
PSU
Cooling module
Enclosure thermal sensor
Service (the Service signal to specify a specific enclosure)
Disk drives
JBOD Identifier:
The managing system will sound the alarm and deliver warning messages if there
is a conflict between JBOD IDs.
If more than one JBOD is connected to the managing RAID system, each JBOD
needs a unique enclosure ID set using the rotary switch on the
. For
example, the firmware automatically disconnects the second JBOD if it is
connected online and comes with an ID identical to that of the first JBOD.
NOTE
The IDs for JBODs are #1 to #15. For details, please refer to
Cooling Module Speed Adjustment:
If any of the detected temperature readings breaches the temperature
threshold, the firmware running on the managing RAID system automatically
raises the rotation speed of all cooling fans.
JBOD Enclosure Status Monitoring:
When connected with expansion JBODs, acquires the component status within
other enclosures via a proprietary enclosure monitoring service using the in-band
connectivity. No additional management connection is required.
Summary of Contents for NVR7312(2U)
Page 1: ...NVR7300 Series User Manual Release 1 2...
Page 72: ...72 1st JBOD 2nd JBOD Last JBOD...
Page 92: ...92...
Page 98: ...98 2 Click the Apply button to apply the schedule and OK to exit the dialog...
Page 100: ...100...
Page 127: ...127...
Page 249: ...249 Jumps to the next segment The play speed can be adjusted from 1x to 8x...
Page 286: ...286 12 5 5 FTP Setting It allows you to configure FTP server settings...
Page 336: ...336 2 Accept the terms in the license agreement and click Next...