3-24
Netra 210 Server Service Manual • March 2006
Note –
The connectors for the CPU0 heat sink fans are labeled
P0 F0
and
P0 F1
on
the system board, and the connectors for the CPU1 heat sink fans are labeled
P1 F0
and
P1 F1
.
6. Unlock the heat sink from the CPU socket by first pressing down on the fasteners
securing the heat sink assembly and then lifting them up.
See
FIGURE 3-31
. Repeat this step for both fasteners on the heat sink.
FIGURE 3-31
Unlocking the Heat Sink Fasteners
7. Perform the appropriate step for your situation:
■
If the heat sink is free after the heat sink fasteners are disconnected, carefully
remove the heat sink. See
FIGURE 3-32
.