4-20
Netra 210 Server Service Manual • March 2006
■
Otherwise, replace the SAS IF assembly.
Go to
Step 3
of
Section 4.6.2, “Installing the SAS IF Assembly” on page 4-20
.
4.6.2
Installing the SAS IF Assembly
1. Remove the server from the rack, open the bezel, and remove the top cover and
airduct.
■
See
Section 1.4, “Removing the Server From the Rack” on page 1-4
.
■
See
Section 1.5, “Opening the Bezel” on page 1-5
.
■
See
Section 1.6, “Removing the Top Cover” on page 1-7
.
2. Locate where the SAS IF assembly installs.
The SAS IF assembly installs at the right front of the chassis.
3. Remove the replacement SAS IF assembly from its shipping container and
antistatic packaging.
4. Lower the SAS IF assembly into position.
See
FIGURE 4-26
.
FIGURE 4-26
Lowering the SAS IF Assembly into the Chassis
5. Using the No. 2 Phillips screw driver, tighten the two screws to secure the SAS IF
assembly to the chassis.
See
FIGURE 4-27
.