Appendix A
Specifications
A-3
A.5
NEBS Level 3 Compliance
The DC-powered version of the Netra 210 server meets NEBS Level 3 requirements
per SR-3580, including the appropriate sections of GR-63-CORE (
Network Equipment-
Building System Requirements: Physical Protection
) and GR-1089-CORE (
Electromagnetic
Compatibility and Electrical Safety - Generic Criteria for Network Telecommunications
Equipment
).
Caution –
To maintain NEBS compliance, the network management (NET MGT)
Ethernet port and the RJ45 serial management (SERIAL MGT) port must use
shielded cables and both ends of the shield must be grounded.