ID 442426.04
63
WE KEEP THINGS MOVING
Technical data
4
Manual SD6
Drive controller – braking resistor assignment
Not possible: —
Recommended: X
Possible: (X)
Note the attachment to the drive controller (section 6.6 Bottom brake resistor)!
Dimensions [mm]
4.12 Chokes
To reduce high-frequency currents on electrical cables and thus increase the
interference immunity and availability of drive systems, coils such as network
or output deraters are used – corresponding to your application.
Power chokes
involve inductive metal wire coils that reduce undesired
harmonics or distortion in the network (e.g. for commutation of the current
flow). In addition, they relieve the DC-Link circuit capacity of the drive
controller.
Output deraters
reduce charge current peaks due to the cycle signal and line
capacity. They make long motor cables possible, increase the motor service life
and reduce harmonic currents.
Type
RB 5022
RB 5047
RB 5100
ID no. 45618
ID no. 44966
ID no. 44965
SD6A04
—
—
X
SD6A06
—
—
X
SD6A14
—
X
(X)
SD6A16
—
X
(X)
SD6A24
X
—
—
SD6A26
X
—
—
SD6A34
—
—
—
SD6A36
—
—
—
SD6A38
—
—
—
Type
RB 5022
RB 5047
RB 5100
ID no.
45618
44966
44965
Height
300
300
Width
94
62
Depth
18
18
Drilling pattern corresponds to
size
2
1
0 and 1