![Stober SD6 Series Manual Download Page 395](http://html.mh-extra.com/html/stober/sd6-series/sd6-series_manual_1381243395.webp)
ID 442426.04
395
WE KEEP THINGS MOVING
Diagnosis
16
Manual SD6
16.24 54:following Error
Triggering
Level
Response
Counter
The difference between the actual and target
position exceeds the parameterized maximum
allowable following error.
Parameterized
level in
U22
:
•
Inactive
•
Message
•
Warning
•
Fault
Parameterized fault response in
A29
:
•
A29 = 0:inactive
The power board is switched off and the drive
becomes torque-free/force-free. If the air override is
inactive, a possibly existing brake will be controlled to
close.
•
A29 = 1:active
The drive is stopped with a quick stop. If the air
override is inactive, a possibly existing brake will be
controlled to close at the end of the quick stop.
Z54
Possible cause
Test
Measure
Confirmable
The control deviation of the position is
greater than the parameterized
maximum allowable following error.
•
Check whether there is a mechanical
blockage, for example in the mechanical
system or because a brake is not
released.
•
Rectify mechanical blockages.
•
If there is a holding brake: Check
parameterization in
F00
and the
following parameters.
•
For vertical axes with hydraulic or
pneumatic weight compensation: Check
whether there is sufficient pressure
available.
•
Check the following error parameters
A546, A547
and
I21
.
•
Check control parameters
C03
,
C05
,
C31
,
C32
,
I20 and
I25
Yes