![Stober SD6 Series Manual Download Page 256](http://html.mh-extra.com/html/stober/sd6-series/sd6-series_manual_1381243256.webp)
ID 442426.04
256
WE KEEP THINGS MOVING
Encoder
12
Manual SD6
12.6 Connection X101 (binary input encoder)
Encoder connection X101 is an integral part of terminal module XI6.
You can simulate or evaluate the following encoders on X101:
•
Incremental encoder
•
Stepper motor encoder
For detailed information regarding the relevant encoder specification and
supply as well as the corresponding terminals, see 7.4.2 X101.
Function of encoder evaluation on BE3 (X101.13), BE4 (X101.14) and BE5
(X101.15).
H41
and
H42
together indicate a fraction that is used to convert the raw values
of the encoder connected to X101 into mechanical quantities.
The unit of the mechanical target quantity is revolutions for rotational encoders
and mm for linear encoders.
H41
and
H42
together indicate a fraction that is used to convert the raw values
of the encoder connected to X101 into mechanical quantities.
The parameter indicates whether the encoder connected to X101 is a rotational
or translational measuring system. This affects the unit of measure of
H41
and
where the encoder is located in the axis model in relation to the feed.
12.7 Connection X140
Encoder connection X140 is an integral part of terminal module RI6.
You can evaluate the following encoders on X140:
•
Encoder EnDat digital
•
Encoder EnDat Sin/Cos
•
Sin/cos encoder
For detailed information regarding the relevant resolver or encoder
specification, the encoder supply as well as the corresponding terminals, see
Function of the X140 connector on the RI6 I/O terminal module.
H40
BE-encoder
version 0
0: inactive
1: incremental encoder in
•
BE3: Zero track
•
BE4: Chan. A+
•
BE5: Chan. B+
2: stepmotor In
•
BE4: Fr (increments)
•
BE5: Sign+ (direction)
H41
BE numerator
version 0
H42
BE denominator
version 0
H43
encoder type
version 0
H140
X140-function
version 3
Information
Note that a change to
H140
may result in a rescaling of position
values (in positioning applications). Scaling may last for several
hours.
0: inactive
6: Sine cosine
66: resolver
70: EnDat
71: EnDat with sine and
cosine