ID 442426.04
214
WE KEEP THINGS MOVING
Motor
10
Manual SD6
Maximum permitted motor current.
For synchronous servo motors of STOBER, the maximum permitted current
before the motor is demagnetized.
Maximum permitted speed for the motor.
Internally calculated magnetization reference current for asynchronous motors.
(Internally) calculated torque generating reference current.
Equivalent to the rated current for asynchronous motors and the standstill
current for synchronous servo motors.
Display of the current setpoint for the emergency braking that can be activated
with
U30
. This current is defined by the drive controller based on the motor
data. The resulting brake torque is motor-dependent.
Display of the smallest value that can be requested as a reference value for
E92 Id
by control. The current reference value is displayed in
E165 Id-ref
.
10.2.2.3.2
Synchronous linear motor
If you have to enter the motor data for a synchronous linear motor, edit the
following B parameters. The E parameters show internally calculated values.
Shows the motor designation as text.
EMC constant of the motor.
Peak value of the induced voltage between two phases at 1000 rpm for
synchronous servo motors and asynchronous motors or the peak value of the
induced voltage at 1m/s for synchronous linear motors.
B82
I-max
version 0
B83
v-max motor
version 0
E171
Id-reference
version 0
version
Level Axis
type
Data type Signifi.
digits
Enable
off
Unit
Para
type
R W
V 6.0
4 6
Physical
REAL32
No
A
Numb
er
PDO-
capable
Scaling
PKW1 PROFIBUS/
PROFINET
SDO CANopen/
EtherCAT
Factor NKS PNU
Subindex
Index
Subindex
No
1
3
28ABhex
0000hex
28ABhex
0000hex
Default
PreRead
PreWrite
PostRead
PostWrite
0
0
0
0
LSB
Final value
Scaling
Hiding
DepFlags
0
0
0
E172
Iq-reference
version 0
E940
emergency stop current
version 0
E941
Id-minimum
version 0
B00
motor-type
version 0
B02
back EMF
version 0