![Stober SD6 Series Manual Download Page 413](http://html.mh-extra.com/html/stober/sd6-series/sd6-series_manual_1381243413.webp)
ID 442426.04
413
WE KEEP THINGS MOVING
Diagnosis
16
Manual SD6
18:Battery empty (EBI)
The AES accessory battery is empty.
•
Replace the battery. Follow the
instructions in the AES operating
manual.
Yes
20:resol.carrier
The resolver could not be calibrated or
optimized.
•
Check the encoder cable.
•
Check whether the specification of the
resolver matches the specifications of
STOBER.
•
Please contact our Service department.
No
21:X140-undervolt.
Incorrect transfer factor
22:X140-Overvltg
24:resol.failure
Wire break
•
Check the encoder cable.
•
Please contact our Service department.
Yes
30:X120-Wire break
A wire break was detected at X120.
•
Check the connected cable (encoder or
SSI connection).
•
Check the power supply of the SSI
encoder or the source that simulates the
SSI signals.
•
Make sure that the settings of the SSI
master are matched to the SSI encoder
or the source that simulates the SSI
signals.
Yes
35:X120-double transmission
Different positions are frequently
determined at X120 during double
transmission.
•
Check the encoder cable.
•
Please contact our Service department.
No
36:X120-Busy
Encoder has not responded for too long.
•
Replace the option board that the
encoder is connected to.
•
Replace the drive controller.
•
Please contact our Service department.
Yes
38:X120-Timeout
No cycle signal was detected from the SSI
master.
•
Check the connected cable.
•
Check the power supply of the SSI
master.
Yes
Cause
Description
Measure
Confirmable