![Stober SD6 Series Manual Download Page 394](http://html.mh-extra.com/html/stober/sd6-series/sd6-series_manual_1381243394.webp)
ID 442426.04
394
WE KEEP THINGS MOVING
Diagnosis
16
Manual SD6
Cause
Description
Measure
Confirmable
1:HW limit switch positive
The drive has reached the positive
hardware limit switch.
•
Move back in the opposite direction from
the limit switch into the travel range.
•
Check the connection of the hardware
limit switches.
•
Check the parameterization of the signal
source in
I101
and
I102
.
Note that if limit switches are crossed, after
acknowledgement you must jog back into
the permitted range with the drive.
Yes
2:HW limit switch negative
The drive has reached the negative
hardware limit switch.
3:SW limit switch positive
The drive has reached the positive software
limit switch.
•
Move back in the opposite direction from
the limit switch into the travel range.
•
Check the position of the software limit
switches in
I50
and
I51
.
Note that if limit switches are crossed, after
acknowledgement you must jog back into
the permitted range with the drive.
Yes
4:SW limit switch negative
The drive has reached the negative
software limit switch.
5:Computing limit
The computing limit has been reached.
•
Reduce
I06 decimal digits position
.
•
Do not perform
MC_MoveAdditive
too
many times in a row without stopping in
between
Yes