The following conditions apply for changes of state:
Change of state
Conditions
0
Device start-up > Not ready to switch on
Control board power supply turned on
1
Not ready to switch on > switch on disable
Self test completed without errors
AND
initialization complete
2
Switch on disable > ready to switch on
(Release inactive
9.2.3.1 STOBER device state machine
OR
Autostart active
AND
DC link charged
c)
AND
safety technology deactivated
AND
one axis active
d)
AND
IGB motion bus inactive
e)
OR
(IGB motion bus active
f)
AND
(IGB state =
3:IGB
motion bus
f)
OR
IGB exception mode active
OR
Local mode
active
h)
3
Ready to switch on > switched on
Enable active
a)
4
Switched on > operation enabled
Enable active
a)
5
Switched on > ready to switch on
Enable inactive
a)
6
Ready to switch on > switch on disable
DC link not charged
c)
OR
safety technology active
d)
OR
Axis inactive
e)
OR
(IGB motion bus active
f)
AND
IGB state not equal to
3:IGB motion bus
g)
AND
IGB exception mode
inactive
h)
AND
Local mode inactive
i)
)
7
Operation enabled > quick stop active
Signal
quick stop
active
i)
OR
(enable inactive
a)
AND
quick stop
signal with enable off
active)
g)
8
Quick stop active > operation enabled
Enable active
a)
AND
quick stop
signal inactive
j)
AND
quick stop end reached
j)
9
Quick stop > ready to switch on
Enable inactive
a)
AND
quick stop end reached
j)
10
Quick stop active > switch on disable
Safety technology active
d)