![Stober SD6 Series Manual Download Page 49](http://html.mh-extra.com/html/stober/sd6-series/sd6-series_manual_1381243049.webp)
ID 442426.04
49
WE KEEP THINGS MOVING
Technical data
4
Manual SD6
4.8.3
Specification – IO6
X100 specification
X101 specification
Electrical data
Analog inputs
AE1 and AE2
Level
± 10 V
Resolution 12
bits
Internal resistance
> 40 k
Ω
Refresh rate
Cycle time of the
application
Analog input
AE1 as current input
(AE1+ and AE1 shunt
bridged)
Level
± 20 mA
Resolution
12 bits
Internal resistance
492
Ω
Wire break monitoring
Parameterizable in
F15
Analog outputs
AA1 and AA2
(short-circuit-proof)
Level
± 10 V, ± 20mA
Maximum output current ± 20mA
Electrical data
Binary inputs
BE1 to BE3
Low level
0–8 V
High level
12–30 V
Input voltage
Max. 30 V
Input current
Max. 16 mA
Input frequency
Max. 10 kHz
Binary inputs
BE4 and BE5
Low level
0–8 V
High level
12–30 V
Input voltage
Max. 30 V
Input current
Max. 16 mA
Input frequency
Max. 400 kHz
Binary outputs
BA1 and BA2
Maximum output current 100 mA
Typical voltage drop
< 2 V
Refresh rate
Cycle time of the
application
Binary outputs
BA1 and BA2 as
encoder output
Maximum output current 50 mA
Typical voltage drop
< 2 V
Output frequency
Max. 1 MHz
24-V power supply
Input voltage
18–28.8 V