![Stober SD6 Series Manual Download Page 268](http://html.mh-extra.com/html/stober/sd6-series/sd6-series_manual_1381243268.webp)
ID 442426.04
268
WE KEEP THINGS MOVING
Communication
14
Manual SD6
PC or the internet are connected to a free outer socket. The IGB network is set
up automatically when you turn on at least one drive controller. The following
conditions apply when integrating additional drive controllers into the network:
•
You have connected these drive controllers to the IGB network.
•
The drive controllers in the network must be receiving a 24 vdc power
supply
To start the integration, the 24 vdc power supply of the drive controller in the
network must be turned on. When the 24 vdc power supply is turned on, the
IGB network is restructured and up to 32 connected drive controllers will be
integrated.
14.2.2
Diagnosis
14.2.2.1
IGB network
Number of subscribers currently logged in on the IGB.
•
0
or
1
: No other subscribers are currently connected with this drive
controller via IGB.
•
2
..
32
: The number that is displayed corresponds to the number of drive
controllers found in the IGB network.
IGB status of the drive controller.
Information
MAC address range of the STOBER hardware:00:11:39:00:00:00 -
00:11:39:FF:FF:FF
Information
Remember that sockets X3 A and X3 B are not electrically
connected. If you turn off a device in an IGB network or disconnect
an IGB cable, two partial networks are created to the left and right
of this device or the disconnected cable.
A153
IGB actual node number
version 0
A155
IGB-state
version 0
0: IGB booting
The IGB boots up.
The connected drive controllers declare
themselves in the IGB network and are
synchronized.
1: single
Currently no IGB network is set up with other
drive controllers.
Possible causes:
•
The drive controller has not found any
other drive controllers with which an IGB
network can be set up
•
An already existing connection to other
drive controllers via IGB has been
disconnected