ID 442426.04
29
WE KEEP THINGS MOVING
Technical data
4
Manual SD6
4.1
Notes on safety
Drive controllers are products subject to sales restrictions in accordance with
IEC 61800-3.
The drive controllers are not designed for use in a public low frequency network
that supplies residential areas.
In a residential environment this product may cause high-frequency
interference. If this occurs the user may be asked to take suitable measures.
The drive controllers are not designed for use in a public low frequency network
that supplies residential areas. High-frequency interference can be expected if
the drive controllers are used in a network of this type.
Always operate the devices within the limits specified in the technical data.
The following applications are prohibited:
•
Use in areas subject to explosion hazard
•
Use in environments with harmful substances as specified by EN 60721,
for example oils, acids, gases, vapors, dust and radiation
Implementation of the following applications is only permitted after approval is
obtained from STOBER:
•
Use in non-stationary applications
4.2
Electrical Data
4.2.1
Control board
Information
An explanation of the most important formula symbols can be found
in section 1.5 Abbreviations, formula symbols and indices.
Type
All SD6 drive controller types
U
1CU
20.4 – 28.8 V
I
1maxCU
a)
a) Depending on the accessories used.
1.5 A
P
V,CU
(I
2
= 0 A)
b)
b) Depending on the option modules and encoders connected.
Size 0 – Size 2: max. 30 W
Size 3: max. 55 W