148
AXP1440-C07 Installation and Use (6806800V18A)
Shelf Management Module
Shelf Management Module
In abnormal operating conditions, when a blade thermal sensor is approaching or crossed
its upper noncritical threshold, the SAM1620-D automatically adjusts the fan speeds to a
point where all the blade thermal sensors are just below their upper noncritical threshold
(minus a user configurable offset).
The dynamic minimum fan level is not used.
Each fan tray has six fan units and each fan unit has an inlet and outlet fan. Fan speeds for
all level settings are summarized in the next table.
7.4.2
Redundancy Control
The ShMM-1500R supports redundant operation using a redundant ShMM-1500R. In a
configuration having ShMM-1500Rs, one acts as an active shelf manager and the other as
a standby. Both ShMM-1500Rs monitor each other, and either module can trigger a
switchover if necessary.
The ShMM-1500R provides a number of hardware redundancy signals on the CN1
connector. The HRI is implemented using the FPGA device. The default operation of the
SAM1620-D is to switchover automatically. The AXP1440-C07 chassis is specially
designed to operate in harsher shock environments with a hot-swap switch of the ShMM-
1500R having potential to trigger, causing the shelf manager switchover without a true
failure in the active shelf manager.
Table 7-8
Fan Speeds for all Levels
Fan Level
Speed in RPMs
1
1800 Inlet, 1100 Outlet ±10%
10
2600 Inlet, 1500 Outlet ±10%
20
3200 Inlet, 2000 Outlet ±8%
30
3900 Inlet, 2400 Outlet ±8%
40
4500 Inlet, 2900 Outlet ±5%
50
5100 Inlet, 3300 Outlet ±5%
60
5800 Inlet, 3700 Outlet ±5%
70
6400 Inlet, 4200 Outlet ±5%
80
7000 Inlet, 4500 Outlet ±5%
90
7600 Inlet, 5000 Outlet ±5%
100
8000 Inlet, 5200 Outlet ±5%
Summary of Contents for 6806800V18A
Page 1: ...AXP1440 C07 Installation and Use P N 6806800V18A February 2020...
Page 8: ...6 AXP1440 C07 Installation and Use 68068000V18A Table of Contents...
Page 10: ...List of Figures 8 AXP1440 C07 Installation and Use 68068000V18A...
Page 12: ...List of Tables 10 AXP1440 C07 Installation and Use 68068000V18A...
Page 40: ...38 AXP1440 C07 Installation and Use 6806800V18A Notice de S curit Notice de S curit...
Page 52: ...50 AXP1440 C07 Installation and Use 6806800V18A Sicherheitshinweise Sicherheitshinweise...
Page 90: ...88 AXP1440 C07 Installation and Use 6806800V18A Site Preparation Site Preparation...
Page 163: ...1...