TC63 AT Command Set
18.12 AT^SNFM
s
TC63_ATC_V00.490
Page 423 of 501
5/24/05
Confidential / Draft - Do not copy
18.12
AT^SNFM Set microphone audio path and power supply
The
AT^SNFM
read command returns the microphone mute and supply voltage status.
The
AT^SNFM
write command can be used to switch the microphone's audio path (muted / not muted) or to con-
trol the power supply of the VMIC line for the two microphone inputs.
The microphone can be muted or activated by changing
<MicSwitch>
in all audio modes (1 to 6) and during a
voice call only. As an alternative, you can use the
AT+CMUT
command to mute the microphone.
Syntax
Parameter Description
Microphone mute control parameter.
Evaluated during voice calls and if
<MicVccCtl>
is omitted only, e.g.
AT^SNFM
=1.
Command does not depend on audio mode.
0
Mutes the microphone.
1
(P)
Activates the microphone.
Microphone supply voltage control parameter. Controls the power supply VMIC of the two microphone inputs.
CME error is given if
<MicSwitch>
is not omitted. Enter for example
AT^SNFM
=,1 or
AT^SNFM
=,2.
0
Supply voltage is always switched off.
1
Supply voltage is always switched on.
2
(P)
Supply voltage state during voice calls is controlled by the ME. Actual value is
determined by parameter data set of the selected audio mode.
Test Command
AT^SNFM=?
Response(s)
^SNFM:
(list of supported
<MicSwitch>
s) , (list of supported
<MicVccCtl>
s)
OK
Read Command
AT^SNFM?
Response(s)
^SNFM:
<MicSwitch>
,
<MicVccState>
OK
Write Command
AT^SNFM=
[
<MicSwitch>
][,
<MicVccCtl>
]
Response(s)
OK
ERROR
+CME ERROR:
<err>
Reference(s)
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
SIEMENS
!
%
%
%
%
%
%
!
%
!
<MicSwitch>
(num)
<MicVccCtl>
(num)