TC63 AT Command Set
8.7 AT^SMOND
s
TC63_ATC_V00.490
Page 190 of 501
5/24/05
Confidential / Draft - Do not copy
8.7
AT^SMOND Cell Monitoring
The
AT^SMOND
execute command can be used to obtain status information of the service cell and up to six neigh-
bour cells. The advantage over other cell monitoring commands is that
AT^SMOND
delivers more detailed infor-
mation about the received signal strength.
Syntax
Parameter Description
Serving cell information (comma-separated, no cr/lf included)
<MCC>
,
<MNC>
,
<LAC>
,
<cell>
,
<BSIC>
,
<chann>
,
<RxLev>
,
<RxLev>
Full,
<RxLev>
Sub,
<RxQual>
,
<RxQual
>
Full,
<RxQual>
Sub,
<Timeslot>
If no serving cell is found, unavailable values are omitted:" ,,,,,,
<RxLev>
,,,0,,,0"
Neighbour cell information for neighbour cell 1 through 6 (comma-separated, no cr/lf included)
<MCC>
1
,
<MNC>
1
,
<LAC>
1
,
<cell>
1
,
<BSIC>
1
,
<chann>
1
,
<RxLev>
1
, (these parameters repeated for neighbour
cells 2 through 6 with no CR/LF): ...
<MCC>
6
,
<MNC>
6
,
<LAC>
6
,
<cell>
6
,
<BSIC>
6
,
<chann>
6
,
<RxLev>
6
An unavailable cell appears as follows: " ,,,,,,0"
Values for RSSI and BER (comma-separated, no cr/lf included)
<RSSI>
,
<BER>
Mobile country code
3 digits, e.g. 232
000
Not decoded
Test Command
AT^SMOND=?
Response(s)
OK
ERROR
+CME ERROR
Exec Command
AT^SMOND
Response(s)
^SMOND:
[
<sci>
][,
<nci>
][,
<TA>
][,
<rssiber>
]
OK
ERROR
+CME ERROR
Reference(s)
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
SIEMENS, 3GPP TS 05.08
%
%
%
%
%
%
%
!
!
!
<sci>
(str)
<nci>
(str)
<rssiber>
(str)
<MCC>
(num)