![Siemens SINAMICS G150 Operating Manual Download Page 220](http://html.mh-extra.com/html/siemens/sinamics-g150/sinamics-g150_operating-manual_378200220.webp)
Technical Data
11/03
SINAMICS G150
12-12
Operating Manual
Table 12-13 Version A, 660 V – 690 V, part 2
Category Unit
Order no.
6SL3710-
1GH31-5AA0 1GH31-8AA0 1GH32-2AA0
Rated motor output
kW
132
160
200
Rated connection voltage
V
3 AC 660 V to 690 V ±10 % (-15 % < 1 min)
Rated input current
A
174
201
234
Rated output current
A
150
175
215
Base load current
A
140
171
208
Power loss
kW
2.8
3.8
4.2
Cooling air requirement
m³/s
0.17
0.36
0.36
Sound pressure level at 50/60
Hz
dB(A) 67/68
69/73
69/73
Power connection
Recommended: DIN VDE
AWG / MCM
Maximum: DIN VDE
AWG / MCM
Fastening screw
mm
2
mm
2
95
(4/0)
4 x 240
4 x (600)
M12 (2 holes)
120
(300)
4 x 240
4 x (600)
M12 (2 holes)
2 x 70
2 x (000)
4 x 240
4 x (600)
M12 (2 holes)
Motor connection
Recommended: DIN VDE
AWG / MCM
Maximum: DIN VDE
AWG / MCM
Fastening screw
mm
2
mm
2
95
(4/0)
2 x 150
2 x (400)
M12 (2 holes)
120
(300)
2 x 150
2 x (400)
M12 (2 holes)
2 x 70
2 x (000)
2 x 150
2 x (400)
M12 (2 holes)
Protective earth connection
Fastening screw
M12 (2 holes)
M12 (2 holes)
M12 (2 holes)
Approx. weight (standard
version)
kg 320
390
390
Dimensions (w x h x d)
mm
800 x 2000 x 600
800 x 2000 x 600
800 x 2000 x 600
Recommended protection
Conductor protection
(with option L26)
Rated current
Size to DIN 43 620-1
Cond./semi-cond. protection
(without option L26)
Rated current
Size to DIN 43 620-1
A
A
3NA3 240-6
200
2
3NE1 225-2
200
1
3NA3 244-6
250
2
3NE1 227-2
250
1
3NA3 252-6
315
2
3NE1 230-2
315
1
Summary of Contents for SINAMICS G150
Page 2: ......
Page 22: ...Device Overview 11 03 SINAMICS G150 2 10 Operating Manual ...
Page 196: ...Diagnosis Faults and Alarms 11 03 SINAMICS G150 10 54 Operating Manual ...
Page 208: ...Maintenance and Servicing 11 03 SINAMICS G150 11 12 Operating Manual ...
Page 234: ......
Page 238: ...Parameterlist 11 03 SINAMICS G150 Parameterlist 4 Operating Manual ...
Page 239: ......