Image processing
3.2 Code verification
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
71
3.2.9.4
Standard report for AS9132, Rev A
Table 3- 13 Output parameters: AS9132, Rev A
Field name (String input)
Value
Verification type (Qt)
3
If the exposure settings do not comply with the
standard: D
Evaluation (Qs)
3 (Good), 2 (Fair), 1 (Poor)
Overall grade (Q0)
4 ... 0
Module size offset grade (Q20)
4, 3, 0
Module size offset 1 (q20)
0 ... 99.9
Module size offset 2 (q20)
0 ... 99.9
Module center offset grade (Q19)
4, 3, 0
Module center offset 1 (q19)
0 ... 99.9
Module center offset 2 (q19)
0 ... 99.9
Angle of distortion grade (Q22)
4, 3, 0
Angle of distortion (q22)
-45 ... 45
Ovality grade (Q23)
4, 3, 0
Ovality (q23)
0.00 ... 99.9
Module fill X (q9)
0 ... 200
Module fill Y (q9)
0 ... 200
Contrast (q1)
0 ... 100
Nominal module size (q10)
0 ... 99.9 mil
ECCLevel (q14)
200
Height (q15)
0 ... 9.99 inch
Width (q16)
0 ... 9.99 inch
Angle (q17)
0 ... 360°