Connection
6.2 Power supply using Power over Ethernet (PoE)
SIMATIC MV500
116
Operating Instructions, 03/2021, C79000-G8976-C494-05
Only connect safety extra-low voltage (SELV) according to IEC 62368-1
WARNING
Operation with safety extra-low voltage
The device is designed for operation with safety extralow voltage (SELV). This means that
only safety extra-low voltages (SELV) according to IEC 62368-1 can be connected to the
power supply terminals.
The power unit for supplying the device must comply with NEC Class 2 as described by the
National Electrical Code(r) (ANSI/NFPA 70).
The power of all connected power supply units must total the equivalent of a power source
with limited power (LPS limited power source).
6.2
Power supply using Power over Ethernet (PoE)
"Power over Ethernet" (PoE) is a power supply technology for network components
complying with IEEE 802.3af.
•
The power is supplied over the Ethernet cables used to connect the individual network
components (corresponding to IEEE 802.3af) with one another. This makes an additional
power cable unnecessary.
•
SIMATIC MV500 is a PD (Powered Device), Type 1, Class 3 (max. 12.95 W)
Note that the power supply via POE is only possible via the "X1 LAN1" Ethernet interface.
When using the POU power supply, you must enable the setting "Settings > Options >
Lighting > Power via POU or CM".
Restriction of the power supply type
The IEEE standard 802.3af specifies two types of power supplies:
•
Voltage via wire pairs that are not used for data transmission (redundant wires).
•
Voltage via wire pairs that are used for data transmission (phantom power).
The Ethernet connection of the SIMATIC MV500 optical readers is four-wire. Power can only
be suppled via these four wires with phantom power. The voltage feeding device must
provide the phantom power.
The following Siemens switches with PoE provide phantom power:
•
SCALANCE X108 POE
•
SCALANCE XP208 POE EEC
•
SCALANCE XP216 POE EEC
•
SCALANCE X308-2M POE
•
SCALANCE XR324-4M POE
•
SCALANCE XR324-4M POE TS
Summary of Contents for SIMATIC MV500
Page 10: ...Preface SIMATIC MV500 10 Operating Instructions 03 2021 C79000 G8976 C494 05 ...
Page 16: ......
Page 28: ......
Page 32: ......
Page 92: ......
Page 114: ......
Page 148: ......
Page 244: ......
Page 254: ......
Page 260: ......
Page 292: ......
Page 294: ...Service Support SIMATIC MV500 294 Operating Instructions 03 2021 C79000 G8976 C494 05 ...