Process interfacing via an automation system (PLC, PC)
9.3 Control with Ident profile
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
163
Table 9- 19 Memory area of the receive data (TXREF or RXREF)
Address
Value
Meaning
0x0000
0x05
Command identifier
"Set DISA bit"
Command: Reset DISA bit
The command data to be "written" in the "PHYSICAL WRITE" command only contains the
command identifier "Reset DISA bit".
If the "DISA" bit of the optical reader has been reset, the command receives positive
acknowledgment. If it was already reset, this command has no effect but is nevertheless
positively acknowledged.
The "PHYSICAL WRITE" command must specify the length "0x01" ("CMD_STRUCT.Length =
0x01"); otherwise, the command receives a negative acknowledgment.
Table 9- 20 CMD_STRUCT
Parameter
Value
CMD
0x71
OffsetBuffer
0x00
UID
0x00
Length
0x01
StartAddress
0x00
Table 9- 21 Memory area of the receive data (TXREF or RXREF)
Address
Value
Meaning
0x0000
0x06
Command identifier
"Reset DISA bit"
Command: Set digital out
Writing command data
The command data to be "written" in the "PHYSICAL WRITE" command contains the command
identifier and six parameters.
With this command, the four logical signals "EXT_1", "EXT_2", "EXT_3" and "EXT_4" can be set
and linked to other logical signals. These signals can only be set through an automation
system. In addition, these signals can be applied to the available digital output pins via the
WBM.
Receipt of this command is logged in the diagnostics data records. If the command contains
an invalid parameter, a negative acknowledgement is sent.
Summary of Contents for SIMATIC MV500
Page 10: ...Preface SIMATIC MV500 10 Operating Instructions 03 2021 C79000 G8976 C494 05 ...
Page 16: ......
Page 28: ......
Page 32: ......
Page 92: ......
Page 114: ......
Page 148: ......
Page 244: ......
Page 254: ......
Page 260: ......
Page 292: ......
Page 294: ...Service Support SIMATIC MV500 294 Operating Instructions 03 2021 C79000 G8976 C494 05 ...