Description
1.7 Functional description
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
27
Compatibility with MV400
The functions, communication protocols and configurations are largely compatible with the
devices of the SIMATIC MV400 series. The device configurations for these devices can be
imported into the readers of the SIMATIC MV500, enabling a seamless transition from
SIMATIC MV400 to MV500.
Note that after importing an MV400 device configuration, the program must be saved again.
Table 1- 1
Differences / possible incompatibilities
SIMATIC MV400
SIMATIC MV500
Digital inputs
/outputs
DI trigger, DQ strobe,
4 configurable DI/DQs
DI trigger, DQ strobe,
2 DQs
RS232 interface
9.6 ... 115 KB
1 ◆ 1.5 ◆ 2
stop bits
9.6 ... 115 KB
1 ◆ 2 stop bits
DISA bit (via)
RS232, CM, TCP/IP, PN, DI
RS232, CM, TCP/IP, PN
DHCP modes
Client and server
Client
(CONNECT button)
WebAPI
✓
✓
(incompatible with MV400)
The MV400 "Resolution, half" function is no longer available on MV500 due to faster image
acquisition times.
NOTICE
Compatibility restrictions
Note that the following functions are not supported by MV400 in the software versions ≤
V2.0:
•
Calibrated verification (Veri-Genius license),
•
Vericode
•
OCR (Text Genius) and
•
Locator function (Pat genius)
Summary of Contents for SIMATIC MV500
Page 10: ...Preface SIMATIC MV500 10 Operating Instructions 03 2021 C79000 G8976 C494 05 ...