Connection
6.3 Connecting the reader
SIMATIC MV500
122
Operating Instructions, 03/2021, C79000-G8976-C494-05
Table 6- 3
Industrial Ethernet connecting cable M12 (male, 4-pin) / M12 (male, 4-pin)
Pin
Wire color
Signal name
Meaning
1
Yellow
TxD_P
Send data +
2
White
RxD_P
Received data +
3
Orange
TxD_N
Send data -
4
Blue
RxD_N
Received data -
Figure 6-5
Pin assignment of "X2 LAN2" Ethernet socket (M12, 8-pin)
②
Table 6- 4
Industrial Ethernet connecting cable M12 (male, 8-pin) / M12 (male, 8-pin)
Pin
Wire color
Signal name
1
Orange/white
TxD/RxD+2
2
Orange
TxD/RxD-2
3
Green/white
TxD/RxD+1
4
Green
TxD/RxD-1
5
Brown/white
TxD/RxD+3
6
Brown
TxD/RxD-3
7
Blue/white
TxD/RxD+4
8
Blue
TxD/RxD-4
Note
Cable assembly for connection to IE RJ45 interface
To connect the "X2 LAN2" interface (M12, 8-pin) with an IE RJ45 interface, you need to
replace one of the M12 connectors of the cable "6XV1878-5Gxxx" with the IE connector FC
RJ45 ("6GK1901-1BB12-2AA0"). For strain relief to be guaranteed, you need to enlarge the
assembled cable to a length of approx. 5 - 10 cm behind the replaced connector using an
adhesive tape to Ø 8.
Summary of Contents for SIMATIC MV500
Page 10: ...Preface SIMATIC MV500 10 Operating Instructions 03 2021 C79000 G8976 C494 05 ...
Page 16: ......
Page 28: ......
Page 32: ......
Page 92: ......
Page 114: ......
Page 148: ......
Page 244: ......
Page 254: ......
Page 260: ......
Page 292: ......
Page 294: ...Service Support SIMATIC MV500 294 Operating Instructions 03 2021 C79000 G8976 C494 05 ...