Connection
6.3 Connecting the reader
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
121
Communication module cable
You use the CM adapter cable to connect the communication modules (e.g. RF180C and ASM
456) to the optical reader. The communication module cable is pre-fabricated.
Note that when using the power supply via the communication module, you must enable the
setting "Settings > Options > Lighting > Power supply via POU or CM".
Figure 6-3
Pin assignment of communication module plug
Table 6- 2
Communication module cable, M12 (female, 12-pin) / M12 (male, 8-pin)
Pin
Wire color
Signal name
Meaning
1
White
24 V
24 V DC power supply
2
Brown
TxD_N
Send data -
3
Green
0 V
0 V DC power supply
4
Yellow
TxD_P
Send data +
5
Gray
RxD_P
Received data +
6
Pink
RxD_N
Received data -
7
Blue
Not connected
--
8
Red
Shield
--
Pin assignment ↔ socket/wire color of the cable/signal connector of the optical reader
Industrial Ethernet connecting cable
Connect a PC/PG (for control and operation) to the optical reader using a prefabricated
Ethernet cable.
Attach the Ethernet cable to a switch to connect the optical reader to an S7 controller via
onboard PROFINET IO.
Figure 6-4
Pin assignment of "X1 LAN1" Ethernet socket (M12, 4-pin)
③
Summary of Contents for SIMATIC MV500
Page 10: ...Preface SIMATIC MV500 10 Operating Instructions 03 2021 C79000 G8976 C494 05 ...
Page 16: ......
Page 28: ......
Page 32: ......
Page 92: ......
Page 114: ......
Page 148: ......
Page 244: ......
Page 254: ......
Page 260: ......
Page 292: ......
Page 294: ...Service Support SIMATIC MV500 294 Operating Instructions 03 2021 C79000 G8976 C494 05 ...